Manual mode ProMax ClearDrain 7000
The pump remains permanently switched
on if the float switch is set vertically and
the cable points downward.
N O T E
The pump can run dry in manual mode.
•
Switch off the pump when the minimum
water level is reached.
•
Running the pump dry increases wear.
D
•
Move the handle into the horizontal po-
sition and push the cable directly at the
transition to the float switch into the ca-
ble clip such that the float switch is in a
vertical position.
Automatic mode ProMax ClearDrain
11000/14000
The pump switches on when the rising wa-
ter reaches the sensor.
Metal contacts at the bottom of the sensor
strip detect the minimum water level
(switch-off point). When the minimum wa-
ter level is reached, the pump switches off.
E
•
Fit the sensor onto the sensor strip in
the desired switch-on position.
Manual mode ProMax ClearDrain
11000/14000
F
The pump is switched on when the sensor
is inserted in the top-most position of the
sensor strip.
Metal contacts at the bottom of the sensor
strip detect the minimum water level (de-
activation point). When the minimum wa-
ter level is reached, the pump switches off
with a brief delay.
•
Repeat the process: Reinsert the sen-
sor in the top position of the sensor strip.
Setting the residual water level
The pump can pump the water down to a
depth of 6 mm to 8 mm or down to 1 mm.
G
•
Residual water level 6 … 8 mm: Fit
the
spacer ring and secure with the retain-
ing ring (bayonet closure).
•
Residual water level down to 1 mm
(shallow extraction): Release the retain-
ing ring (bayonet closure) and remove
the spacer ring.
N O T E
Shallow extraction is only possible in
manual mode.
Installing the pump
H
•
Install the pump in a horizontal and sta-
ble position in the water.
•
If it needs to be lowered into a well or a
shaft, fasten a rope to the handle. Do
not carry it by the power connection
cable.
•
Install the pump such that it does not
take in dirt particles with a size >5 mm,
which would block the intake. Install the
pump in a raised position if necessary.
•
ProMax ClearDrain 7000: Ensure that
the float switch can always move freely.