During commissioning, 

Er88

 is indicated in the display of the control system, 

  for as long as the final water level is not reached in the filter container, 

  when the pump status detection is not correctly set. 

If the filter system operates correctly, the system message will reset automatically. 

 

 

 

 

 

 

5.1 

Pump fed system 

 

5.1.1  Order of starting up steps 

How to proceed: 

 

 E 

 

1.  Close the slide valve for the dirt outlet at the bottom of the container. 
2.  Check that the entire filter system (pipes and hoses) is complete. 
3.  Remove the container cover. 

–  The filter drum is stopped for safety reasons if the filter cover is lifted and 

Er11

 is indicated in the 

display of the control system. 

 

 

 

 

 

Moving bed filter chamber 

The moving bed filter chamber contains three 20 l sacks of Hel-X 13 biomedia (60 l). Optionally, 80 l can 

be used (supplementary kit Order No.: 43383). 
4.  Tip the Hel-X biomedia from the bags into the moving bed filter chamber. 

–  Ensure that the Hel-X biomedia can move around freely in the container. 

–  It can take several weeks for the Hel-X biomedia to become completely colonised. Uncolonised 

Hex-X biomedia tend to float more. 

 

 

 

When using the supplementary kit, add the biomedia gradually. We recommend adding max. 5 l per 

week. 

 

 

 

 

 

 

 

 

Filter drum 

5.  Manually turn the filter drum for one whole rotation to ensure unobstructed movement. 
6.  Fill the filter with water until the rinsing pump is submerged (dry run protection of the rinsing pump). 
7.  Fit the container cover. 

 

 

 

Switching on the control system and additional units, checking the pipes 

8.  Switch on the control system and perform any necessary adjustments. 

(→ 

Operation) 

9.  Switch on the filter pump and UVC clarifier (if applicable). 

–  Ensure that the water is returned to the pond via the return pipe. 

10. Check all pipes, hoses and their connections for leaks. 

–  Expansion seals may leak initially until they have fully expanded on contact with water. 

11. 

Adjust the level detection device, if necessary. (→ 

Setting the level detection device) 

 

 

 

New filters take approx. 3 to 4 weeks before the bacteria in the unit are fully established. During this time 

– or at a water temperature of <10 °C – the filter may overflow. In this case the filter does not need to be 

cleaned. 

  When using filter starters, medicines or pond water treatments, leave the UVC pre-clarifier switched 

off for at least 36 hours so as not to impair their efficacy. 

 

 

 

 

 

Downloaded from www.watergardeningdirect.com

Содержание ProfiClear Premium Compact-L EGC

Страница 1: ...ProfiClear Premium Compact L Downloaded from www watergardeningdirect com...

Страница 2: ...2 A ProfiClear0126 Downloaded from www watergardeningdirect com...

Страница 3: ...3 B ProfiClear0125 C ProfiClear0143 D ProfiClear0142 Downloaded from www watergardeningdirect com...

Страница 4: ...4 E ProfiClear0127 Downloaded from www watergardeningdirect com...

Страница 5: ...5 F ProfiClear0128 G ProfiClear0164 Downloaded from www watergardeningdirect com...

Страница 6: ...6 H ProfiClear0129 I ProfiClear0130 Downloaded from www watergardeningdirect com...

Страница 7: ...7 J ProfiClear0131 K ProfiClear0132 L ProfiClear0040 Downloaded from www watergardeningdirect com...

Страница 8: ...8 M ProfiClear0133 N FMR0031 O EGC0003 Downloaded from www watergardeningdirect com...

Страница 9: ...9 P ProfiClear0134 Q R BTC0031 ProfiClear0044 S ProfiClear0136 Downloaded from www watergardeningdirect com...

Страница 10: ...10 T PrifiClear0135 U ProfiClear0041 V ProfiClear0137 Downloaded from www watergardeningdirect com...

Страница 11: ...11 W ProfiClear0138 X Y ProfiClear0140 ProfiClear0141 Z ProfiClear0139 Downloaded from www watergardeningdirect com...

Страница 12: ...ren to carry out cleaning and user maintenance under supervision Ensure that the unit is fused for a rated fault current of max 30 mA by means of a fault current protection device Only connect the uni...

Страница 13: ...56 4 3 4 Connecting the coarse dirt outlet 56 4 3 5 Connecting the dirt outlet 57 4 4 Connecting the control system with EGC box 57 4 4 1 Connecting the control system 57 4 4 2 Connecting the EGC box...

Страница 14: ...vice 72 8 2 Regular tasks 73 8 3 Cleaning the entire filter system 73 8 4 Cleaning the rinsing device 73 8 5 Cleaning the screen element 74 8 5 1 Removing fitting a screen element 74 8 5 2 Decalcifyin...

Страница 15: ...on to a new owner 1 1 Warnings used in these instructions The warning information is categorised by signal words which indicate the extent of the hazard D AN G ER Indicates an immediately dangerous si...

Страница 16: ...acemakers The container cover contains a magnet with a strong magnetic field that may affect the operation of pacemakers or implantable cardioverter defibrillators ICDs Always keep magnets at least 20...

Страница 17: ...em The clean water is returned to the pond through a pipe via gravity Advantages of the pump fed system Minimal installation work required System can be easily extended Simple upstream connection of U...

Страница 18: ...seal 2 56 mm 43 mm 3 mm 17 1 inlet 50 mm 2 For connecting a filter pump 18 2 38 mm 1 inlet closed with sealing plugs For connecting an optional UVC clarifier Bitron 19 3 inlet DN 110 with cover cap 2...

Страница 19: ...ents from approx 408 g fish food per day given optimum conditions If required this can be increased to 80 l or 85 l i e 544 g day or respectively 578 g day The development of the biology in the filter...

Страница 20: ...d G The filter container has four handles for carrying Do not use any other carrying or transport aids e g transport by crane 4 2 Fitting the filter container W ARN IN G Dangerous electrical voltage P...

Страница 21: ...ts Horizontally align the base slab Position the inlet in the pond e g via a water course or waterfall so that it is lower than the outlet of the filter system 4 2 2 Gravity fed system B D System spec...

Страница 22: ...ed system the ideal flow rate per DN 110 supply line is between 6000 l h and 8500 l h Provide sufficient supply lines 4 3 2 Connecting the inlet W ARN IN G The container is made of glass fibre reinfor...

Страница 23: ...from returning If a filter pump each is to be connected to the Bitron and to the connection for the filter pump the pump on the connection for the filter pump can be switched on off as required withou...

Страница 24: ...ighten the union nuts The connections are designed to prevent misconnection First flood the container with water then connect the control system to the mains voltage power supply 4 4 2 Connecting the...

Страница 25: ...and may be exposed to rain How to proceed L 1 Either attach the control system and EGC box to the container wall or use threaded hooks to mount it in different position 2 If the EGC box is attached t...

Страница 26: ...the filter system for the first time to ensure that the filter system is not overloaded by excessively soiled water OASE recommends using the PondoVac pond vacuum cleaner for cleaning the pond This c...

Страница 27: ...iomedia tend to float more When using the supplementary kit add the biomedia gradually We recommend adding max 5 l per week Filter drum 5 Manually turn the filter drum for one whole rotation to ensure...

Страница 28: ...for safety reasons if the filter cover is lifted and Er11 is indicated in the display of the control system Moving bed filter chamber The moving bed filter chamber contains three 20 l sacks of Hel X 1...

Страница 29: ...to proceed R 1 Remove the container cover The filter drum is stopped for safety reasons if the filter cover is lifted and Er11 is indicated in the display of the control system 2 Switch off the filte...

Страница 30: ...for safety reasons if the filter cover is lifted and Er11 is indicated in the display of the control system 2 Switch off the filter pump 3 Switch off the mains voltage ensure that the control system...

Страница 31: ...tra Cleaning EC time dependent cleaning Interval In Pump status detection E7 5 Clean button for starting the manual cleaning cycle and for cancelling the active cleaning cycle LED 6 is lit when the cl...

Страница 32: ...the button 6 5 Settings in the menus Settings can only be made in the menus when the control system is switched on 6 5 1 CL Cleaning time Cleaning Setting the cleaning time changes the duration of th...

Страница 33: ...larly useful for ponds containing fish because even if there is only a small amount of dirt excrement is always removed from the water cycle before it leads to a build up of nutrients Adjust the time...

Страница 34: ...five times after an extended pause to make it easier to read 01 17 01 17 01 17 01 17 01 17 Note If the mains voltage is switched off the counter is reset to 0 Note Due to the self test of the filter...

Страница 35: ...es after an extended pause to make it easier to read 00 00 12 44 00 00 12 44 00 00 12 44 00 00 12 44 Note If the mains voltage is switched off the number of cycles is rounded off to the nearest hundre...

Страница 36: ...nd time dependent cleaning is deactivated Time dependent cleaning is automatically activated by floats after check mode Er33 20 cleaning cycles in succession Manual cleaning Time dependent cleaning Le...

Страница 37: ...matic if the number of cleaning procedures drops below 960 Pond heavily soiled Clean the pond Reduce the amount of soiling Install the filter pump in an elevated position Screen elements heavily soile...

Страница 38: ...ch as string algae are blocking the dirt channel Remove a screen element and clean the dirt channel Filter drum is partially soiled cannot be cleaned Rinsing nozzle clogged Clean the rinsing nozzle re...

Страница 39: ...pump malfunction Check the aerator pump Less movement of the new Hel X biomedia Hel X biomedia are not yet fully colonised It takes several weeks for the biomedia to become colonised by bacteria Wait...

Страница 40: ...agents as they would kill the filter bacteria How to proceed 1 Switch off all filter pumps 2 Switch off all other electrical units of the filter system e g UVC clarifier 3 Gravity fed systems only Clo...

Страница 41: ...Clean from OASE Vinegar and chlorine free household cleaning agent How to proceed 1 Remove a screen element Removing fitting a screen element 2 Descale the screen element using a descaler follow the m...

Страница 42: ...ening device To do this unhook both rubber straps 2 Lift the rinsing pump remove the rubber ring and filter sock Clean all parts in clean water 8 8 Replacing the rinsing pump Remove the inner cover to...

Страница 43: ...ted from frost Take the unit out of operation at water temperatures below 8 C or at the latest when freezing temperatures are to be expected Drain the unit as far as possible clean thoroughly and chec...

Страница 44: ...elements Quantity pces 8 8 Removal of coarse dirt particles Pore size m 60 60 Inlet Quantity pces 1 1 optional 3 1 optional Connection 50 mm 2 DN 110 Outlet Quantity pces 2 2 Connection DN 110 DN 150...

Страница 45: ...entrada ni en la salida Peligro de lesi n por el movimiento de cizalla Atenci n Lea las instrucciones de uso No deseche el equipo en la basura dom stica DA St vbeskyttet St nkvandsbeskyttet Smeltesikr...

Страница 46: ...51990 03 18 Downloaded from www watergardeningdirect com...

Отзывы: