- EN -
24
4.4
Connecting the control system with EGC box
4.4.1 Connecting the control system
The cable harness contains the
connection cables of the signal box, the drum motor and the rinsing pump.
These connection cables have to be connected, the EGC box is already connected.
I
How to proceed:
►
Connect the three connectors of the cable harness
to the sockets of the control system and the
capacitor box.
Hand-tighten the union nuts.
–
The connections are designed to prevent reverse polarity.
–
First flood the container with water, then connect the control system to the mains voltage/power
supply.
4.4.2 Connecting the EGC box
Integration of the filter system into the EGC
network is optional and not necessary for operation. (→
Garden Control System (EGC))
The Connection Cable EGC cable is required for connecting the EGC
box.
The correct fastening of the plug connector is important for a secure connection and an interference
-free
EGC
network.
How to proceed:
I, L, M
1.
Remove the
protection cap from the unit.
2.
Fit the plug connector and secure with the two screws (max.
18 lb-in (2.0 Nm)).
–
Ensure that the rubber seal is clean and fits exactly.
–
Replace the rubber seal if damaged.
3.
Remove the protection cap from
EGC-OUT of the last unit in the EGC
network, fit the terminal resistor
EGC
and secure it with the two screws (max.
18 lb-in (2.0 Nm)).
– Ensure that the terminal resistor EGC instead of an EGC connection cable is installed on EGC-
OUT of the last unit in the EGC
network to ensure that the
EGC
network is closed off properly.
–
The scope of delivery of
InScenio EGC Controller includes a terminal resistor EGC.
4.4.3 Connecting an additional EGC compatible unit
An additional EGC
compatible unit can be connected to the
EGC
box.
►
Ensure the correct connection. (→ Connecting the EGC box
How to proceed:
L, M
1.
Remove the protection cap from
EGC-OUT on the EGC
box and fit the plug connector of the
EGCConnection Cable.
2.
Remove the protection cap from
EGC-IN
on the additional unit and fit the other plug connector of the
EGC Connection Cable.
3.
Remove the protection cap from
EGC-OUT
of the additional unit, fit the terminal resistor and secure it
with the two screws (max.
18 lb-in (2.0 Nm)) or connect another EGC-
compatible unit.
Содержание Profi Clear Premium Compact L US
Страница 1: ...Pro Clear Premium Compact L US...
Страница 2: ...2 A ProfiClear0239...
Страница 3: ...3 B ProfiClear0243...
Страница 4: ...4 C ProfiClear0279 D ProfiClear0164...
Страница 5: ...5 E ProfiClear0129 F ProfiClear0130...
Страница 6: ...6 G ProfiClear0244 H ProfiClear0245 I ProfiClear0169...
Страница 7: ...7 J ProfiClear0240 K ProfiClear0280...
Страница 8: ...8 L EGC0009 M EGC0003 N ProfiClear0134...
Страница 9: ...9 O P PrifiClear0135 Q ProfiClear0041...
Страница 10: ...10 R ProfiClear0137 S ProfiClear0138...
Страница 11: ...11 T U ProfiClear0140 ProfiClear0141 V ProfiClear0139...
Страница 110: ...110 Proficlear0251 Proficlear0252...
Страница 112: ...112 Proficlear0254 Proficlear0255 Proficlear0256...
Страница 114: ...114 Proficlear0259...
Страница 116: ...76481 01 20...