REMEDY OF FAULTS
Malfunction
Cause
Remedy
Unit does not start up.
No mains voltage
Check the mains
voltage.
Impeller unit blocked
Clean
Water level in the unit too low
Top up water
Water flow insufficient
Filter housing or impeller unit soiled
Clean
Impeller unit worn
Replace the impeller unit.
Foam filter clogged
Clean
Ceramic substrate soiled
Clean
Suction basket clogged
Clean suction basket.
Pipework soiled
Clean suction unit, flow-out unit
and hoses.
Insufficient filtering performance Foam filter clogged
Clean
Foam filter worn
Replace
Ceramic substrate soiled
Clean
Ceramic substrate worn
Replace
Increased noise
Air in the filter, vent hose on the pump not correctly
positioned.
Correct the position of the vent
hose.
MAINTENANCE AND CLEANING
•
If necessary, clean with clear water using a soft
brush.
•
Do not use cleaning agents or chemical solutions.
We recommend using OASE PumpClean for remov-
ing calcium deposits.
•
Cleaning and replacement cycles for filter media
are dependent on the size of the aquarium and the
number of fish. Therefore, it is necessary to clean
and replace the filter media as required to ensure
optimum filter performance.
Cleaning/replacing the filter media
N O T E
Thoroughly rinse out all filter material with warm tap
water before using for the first time in order to
remove any soiling.
(→
Prerequisite
•
The unit head is removed. (→
How to proceed:
K, L
•
Remove the foam filter and rinse in warm water or
replace.
•
Rinse the ceramic substrate in warm water or
replace.
–
Before using for the first time, remove the ce-
ramic substrate from the plastic bag, rinse it in
warm water and put it loosely into the filter con-
tainer.
Cleaning/replacing the impeller unit
Prerequisite
•
The unit head is removed. (→
How to proceed:
M
•
Pull the pump lid off downward.
•
Remove the impeller unit, c
lean or replace.
•
Reassemble the unit in the reverse order.
–
Ensure that the two rubber bearings are correct-
ly seated.
–
Ensure that the vent hose is in place and is
pointing upwards so that the air can escape.
Re-installing the unit
•
Reassemble the unit head and filter unit.
(→
WEAR PARTS
•
Foam filters
•
Ceramic substrate
•
Impeller unit
•
Suction cups
Содержание FiltoSmart 60
Страница 1: ...FiltoSmart 60 44407_Gebrauchsanleitung_FiltoSmartFiltoSmartThermo indd 1 08 01 16 14 10...
Страница 2: ...2 FiltoSmart 60 A FST0024 B FST0025...
Страница 3: ...3 C FST0026 D FST0029...
Страница 4: ...4 FiltoSmart 60 E FST0031 F G FST0027 FST0028...
Страница 5: ...5 H FSt0032 I FST0033...
Страница 6: ...6 FiltoSmart 60 J FST0034...
Страница 7: ...7 K L FST0035 FST0030 M N FST0036 FST0037...
Страница 8: ...JP 8 FiltoSmart 60 JP JP A A...
Страница 10: ...JP 10 FiltoSmart 60 H I IN OUT J 1 2 3 4 C N...
Страница 11: ...JP 11 OASE Pump Clean K L...
Страница 13: ...JP 13 1m II...
Страница 19: ......
Страница 20: ...77398 01 20...