Safety guidelines
Filtoclear pressure filter with integrated UVC
-
Caution: Dangerous ultraviolet radiation. The rays from
the UVC lamp are harmful to your eyes and skin! Never
operate the lamp of the Filtoclear UVC outside the casing!
-
Set up the Filtoclear with integrated UVC so that it is safe from
flooding. Secure your Filtoclear so that it will not fall into the pond.
It should be placed at least 2m from the edge of the pond.
-
Always turn the pump on first before starting up the Filtoclear
UVC. The UVC lamp must not be operated without water
flowing through it.
-
Do not use the Filtoclear UVC if the connecting lead, UVC lamp
or casing appear to be defective!
-
Do not use the Filtoclear UVC when there are people in the
water!
- Caution: The built-in temperature monitor in the Filtoclear
UVC automatically switches off the UVC lamp if it overheats.
After it has cooled down, the UVC lamp is automatically
switched back on again.
-
Never open the casing of the UVC or its accessories unless
expressly directed to do so in the instructions.
-
The electrical data of the supply grid must correspond to the
data on the type label.
-
Make sure that the Filtoclear UVC is supplied with a measured
fault current not greater than 30mA via a fault current
protection switch (FI or RCD).
-
Always disconnect the plugs of the Filtoclear UVC and of all
devices that are in the water before you carry out any work on
the Filtoclear!
-
For your own safety, contact an electrician if you have any
questions or problems regarding the electrical connection!
-
Never immerse the device in water!
-
Only operate the Filtoclear UVC from a safety socket. This
must be installed in accordance with the relevant national
regulations (VDE, EN ...). Make sure that the ground conductor
is securely installed all the way to the Filtoclear UVC.
-
Never use installations, adapters, extension or connecting
cables without a safety contact.
-
Mains power cables must have a cross-section not less than
that of a rubber hose line with the code HO5 RNF. Extension
cables must comply with the standard DIN VDE 0620.
Instruction for use
P
max
= 0,2 bar