- EN -
23
INSTALLATION AND CONNECTION
Order of tasks to be carried out:
1.
Fit the unit feet (→
2.
Prepare the filter media (→
3.
As an option: OASE HeatUp Retrofitting (heater)
4.
Install the unit.
–
Install the unit next to or under the aquarium.
Note the maximum head height.
5.
Establish the connections (→
Fitting the unit feed
How to proceed:
K
•
Twist the rubber feet into the openings of the con-
tainer base.
Retrofitting the heater
BioMaster 250/350/600/850 can be retrofitted with
OASE HeatUp.
•
A holding ring is required for fitting (provided in the
delivery scope).
BioMaster
250
350
600
850
Hea
tU
p
25
50
75
100
150
⚫
200
–
⚫
250
–
–
300
–
–
⚫
400
–
–
–
⚫
⚫
recommended
possible
–
not possible
Prerequisite:
•
The pump is switched off.
N O T E
When the filter is filled with water, water may spill
when the heater is inserted.
•
Take measures to collect any spillage.
How to proceed:
L
1.
Unscrew the blind plug counter-clockwise and re-
move.
2.
Push the heater into the holding ring as far as it
goes.
–
Tip: Moisten the glass bulb with water before in-
serting.
3.
Fit the heater. (→
Establishing the connections
Assembling the suction unit
How to proceed:
M
•
Assemble the suction unit.
•
Set the flow rate.
•
Use a coin to turn the flow regulator in the hose
adapter to MAX.
Assembling the flow-out unit
How to proceed:
N
•
Assemble the flow-out unit.
–
The water distributor can be used instead of the
flow-out pipe.
•
Use a coin to turn the flow regulator in the hose
adapter to MAX.
Connecting the hose
The procedure is identical for the inlet (IN) and outlet
(OUT).
How to proceed:
O
•
Fasten the suction unit and flow-out unit in the
aquarium using suction cups.
P
1.
Shorten the hose to the required length.
–
Chose the length so that the hose cannot kink in
the intended installation position.
2.
Screw the union nut onto the hose connector of the
connection unit.
3.
Push the hose onto the hose connector and turn the
union nut counter-clockwise to fix the hose in place.
4.
Push the other end of the hose onto the hose con-
nector at the suction unit/flow-out unit and turn the
union nut counter-clockwise to fix the hose in place.
Содержание BioMaster 250
Страница 1: ...BioMaster 250 350 600 850 BioMaster Thermo 250 350 600 850...
Страница 3: ...3 C 2 1 D 3 2 1 BMR0021 BMR0022...
Страница 5: ...5 I 1 2 3 4x J 2 5 4 4x 1 3 BMR0014 BMR0015 K 4 L 1 2 25 24 23 22 3 BMR0006 BMR0023...
Страница 6: ...6 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 M FSt0015 N BMR0026...
Страница 7: ...7 O BMR0005 P 1 2 4 3 BMR0007...
Страница 9: ...9 U BMR0024...
Страница 10: ...10 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 V 3 2 1 4 W 2 3 1 3 BMR0018 BMR0019 X 2 3 1 BMR0020...
Страница 170: ...BG 170 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 BG 8 A A...
Страница 174: ...BG 174 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 Q 1 R 1 2 3 S LOCK UNLOCK...
Страница 175: ...BG 175 OASE PumpClean...
Страница 177: ...BG 177 V 1 2 3 4 5 W 1 2 3 X 1 2 3 4 5...
Страница 179: ...UK 179 UK 8 A...
Страница 181: ...UK 181 C 1 2 D 1 2 3 E 1 UNLOCK 2 F 1 2 LOCK G 1 UNLOCK 2 H 1 2 I 1 2 3...
Страница 183: ...UK 183 N MAX IN OUT O P 1 2 3 4 Q 1 R 1 2 3 S LOCK UNLOCK...
Страница 184: ...UK 184 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 OASE Pump Clean...
Страница 186: ...UK 186 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 W 1 2 3 X 1 2 3 4 5...
Страница 188: ...RU 188 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 RU 8 A A...
Страница 192: ...RU 192 BioMaster 250 350 600 BioMaster Thermo 250 350 600 850 N MAX IN OUT O P 1 2 3 4 Q 1 R 1 2 3 S LOCK UNLOCK...
Страница 193: ...RU 193 OASE Pump Clean...
Страница 195: ...RU 195 W 1 2 3 X 1 2 3 4 5...
Страница 197: ...CN 197 CN 8 A A...
Страница 201: ...CN 201 OASE PumpClean HeatUp 25 50 75 100 150 200 250 300 400...
Страница 204: ...77553 02 20...