background image

-  EN  - 

13 

 

 

Safety information 

 

Correct electrical installation 

 

  Electrical installations must meet the national regulations and may only be carried out by a qualified electrician. 

  A person is regarded as a qualified electrician if, due to his/her vocational education, knowledge and experience, he 

or she is capable of and authorised to judge and carry out the work commissioned to him/her. This also includes the 

recognition of possible hazards and the adherence to the pertinent regional and national standards, rules and regula-

tions. 

 

  For your own safety, please consult a qualified electrician. 

 

 

Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use (splash

-

proof).

 

 

  Protect the plug connection from moisture. 

 

  Only connect the unit to a correctly fitted socket. 

 

 

 

Safe operation 

  

  Never carry or pull the unit by the electrical cable. 

  

  Route cables such that they are protected from damage and do not present a tripping hazard. 

 

  Never carry out technical changes to the unit. 

 

  Only carry out work on the unit that is described in this manual. If problems cannot be overcome, please contact an 

authorised customer service point or, if in doubt, the manufacturer. 

 

 

  Only use original spare parts and accessories for the unit. 

 

  The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace-

makers or implantable cardioverter defibrillators (ICDs). Always keep magnets at least 0.2

 m away from implanted 

devices. 

 

 

 

Information about this operating manual 

 

Welcome to OASE Living Water. You made a good choice with the purchase of this product 

Aquarius Fountain Set 

Eco 5500/7500/9500

Prior to commissioning the unit, please read the instructions of use carefully and fully familiarise yourself with the unit. 

Ensure that all work on and with this unit is only carried out in accordance with these instructions. 

Adhere to the safety information for the correct and safe use of the unit. 

Keep these instructions in a safe place! Please also hand over the instructions when passing the unit on to a new 

owner. 

 

 

 

Symbols used in these instructions 

 

Warnings 

 

The warning information is categorised by signal words, which indicate the extent of the hazard. 

 

 

 

 

W A R N I N G  

  Indicates a possibly hazardous situation. 

  Non-observance may lead to death or serious injuries. 

 

 

 

 

C A U T I O N  

  Indicates a possibly hazardous situation. 

  Non-observance may lead to slight or minor injuries. 

 

 

 

 

N O T E  

Information for the purpose of clarification or for preventing possible damage to assets or to the environment. 

 

 

 

Additional information 

 

 A  Reference to a figure, e.g. Fig. A. 

 

 

Reference to another section. 

 

 

 

Содержание Aquarius Fountain Set Eco 5500

Страница 1: ...41764 06 15 Aquarius Fountain Set Eco 5500 7500 9500 41764 GAW Aquarius_FountainSet_Eco_A5_end_ 18 06 15 18 12 Seite 2 ...

Страница 2: ... 2 A ARS0014 B ARS0015 ...

Страница 3: ... 3 C ARS0016 D ARS0017 ...

Страница 4: ... 4 E ARS0022 F ARS0018 ...

Страница 5: ... 5 G ARS0019 ...

Страница 6: ...rvision Ensure that the unit is fused for a rated fault current of max 30 mA by means of a fault current protection device Only connect the unit if the electrical data of the unit and the power supply correspond The unit data is to be found on the unit type plate on the packaging or in this manual Possible death or severe injury from electrocution Before reaching into the water always disconnect a...

Страница 7: ... accessories for the unit The impeller unit in the pump contains a magnet with a strong magnetic field that may affect the operation of pace makers or implantable cardioverter defibrillators ICDs Always keep magnets at least 0 2 m away from implanted devices Information about this operating manual Welcome to OASE Living Water You made a good choice with the purchase of this product Aquarius Founta...

Страница 8: ...untains Operate in accordance with instructions Operation under observance of the permissible water quality Water quality The following restrictions apply to the unit Do not use in swimming ponds Never use the unit to convey fluids other than water Never run the unit without water Do not use for commercial or industrial purposes Do not use in conjunction with chemicals foodstuff easily flammable o...

Страница 9: ...again once it has cooled down Isolate the unit before starting any work N O T E Sensitive electrical components Incorrect connection will destroy the unit Do not connect the unit to a dimmable power supply This is how to connect the power supply Switching on Connect the unit to the mains The unit switches on immediately Switching off Disconnect the unit from the mains Environmental Function Contro...

Страница 10: ...too high Note maximum water temperature of 35 C The pump automatically switches on again once the motor has cooled down The impeller unit is blocked Disconnect the power supply and remove ob stacle Then switch the pump on again Pump has run dry Disconnect the power plug and flood the pump Fully submerge the pump for operation in the pond Then switch the pump on again Maintenance and cleaning W A R...

Страница 11: ...rage overwintering The unit is not frost proof and has to be removed and put into storage if minus temperatures are expected How to correctly store the unit Thoroughly clean the unit check it for damage and replace any damaged parts Store the pump submerged and in a frost free environment Protect open plug connections from moisture and dirt Wear parts Impeller unit Spare parts The use of original ...

Страница 12: ...nät Kaapelin pituus Mitat Paino HU Típus Csatlakoztatási feszültség Teljesítményfelvétel Szállítási teljesítmény Vízoszlop Csatlakozók Kábelhossz Méretek Súly PL Typ Napięcie przyłączeniowe Pobór mocy Wydajność pompowania Słup wody Przyłącza Długość kabla Wymiary Ciężar CS Typ Připojovací napětí Příkon Dopravní výkon Vodní sloupec Přípojky Délka kabelu Rozměry Hmotnost SK Typ Napájacie napätie Prí...

Страница 13: ...kasia Mahdollinen vaara sydämentahdistinta käyttäville henkilöille Älä hävitä laitetta tavallisen talousjät teen kanssa Huomio Lue käyttöohje HU Portömített Vízálló 2 m es mélységig Fagy esetén a készüléket szerelje le A készülék veszélyes lehet szívritmus szabályozóval rendelkező személyekre A készüléket nem a normál háztartási szeméttel együtt kell megsemmisíteni Figyelem Olvassa el a használati...

Страница 14: ...rdhet Temperatur FI Suositellut vesiarvot pH arvo Kokonaiskovuus Lämpötila HU A vízre vonatkozó ajánlott értékek pH érték Teljes keménység Hőmérséklet PL Zalecane parametry wody Wartość pH Twardość ogólna Temperatura CS Doporučené hodnoty vody Hodnota pH Celková tvrdost Teplota SK Odporúčané hodnoty vody Hodnota pH Celková tvrdosť Teplota SL Priporočene vrednosti za vodo pH vrednost Skupna trdota ...

Отзывы: