18
AMX0146
Cleaning/replacing the impeller unit
•
Dismantle the pump as shown in the figure.
•
Use a brush under clear water to clean the components.
•
Check all components for damage. Replace damaged or worn components.
•
Assemble the pump in reverse order.
When the impeller is pulled out, the
radial bearing in the motor housing may come loose. During reassembly, check that
it is positioned correctly. If necessary, push the radial bearing into the motor
housing with the wide grooves first.