8
Seasonal Flow Control (SFC)
Activating the SFC function reduces energy costs as the unit automatically optimizes its speed
and with it the water volume and pumping head based on the water temperature.
However, this also means that the SFC function causes the unit to adapt to the individual pond
ecology throughout the year and support the pond biology through temperature-dependent cir-
culation (winter mode, transition mode and summer mode).
The SFC function does not work with dry pump installation. If a skimmer, satellite filter or
OASE InScenio control unit is used, it may be advisable to deactivate the SFC function, de-
pending on the system.
AMX0024
Installation and connection
The pump can be installed submerged (in water) or dry (outside the water).
The use of the pump is only permitted subject to adherence to the specified water quality.
(
•
Pool water or salt water can impair the appearance of the unit. Such impairments are excluded
from the warranty.
WARNING
The power supply carries dangerous electrical voltage and must not be placed directly near wa-
ter. Otherwise, there is a risk of serious injury or death from electric shock.
Install the power supply in a flood-protected position at a distance of at least 6.6 ft (2 m) from
the water.
CAUTION
Rotating components in the area of the intake connection and the pressure connection. Reach-
ing into the connections can lead to injuries.
Please note in particular:
If a unit has stopped due to overload, it can start up unexpectedly!
Do not reach into the opening of the inlet connection or outlet connection while the power
plug is connected.
If the connections are freely accessible, e.g. if no hoses are connected, secure the connections
with a finger guard. The finger guard is available as an accessory.
Содержание AquaMax Eco Expert
Страница 59: ...59 AMX0168...