EN
13
Safety information
Electrical connection
•
Special regulations apply to electrical installation in outdoor areas. Only allow a qualified elec-
trician to perform the electrical installation.
–
The qualified electrician has the required professional training, knowledge and skills to per-
form electrical installations in outdoor areas. The qualified electrician can detect potential
risks and adheres to regional and national standards, regulations and directives.
–
For your own safety, please consult a qualified electrician.
•
Only connect the unit if the electrical data of the unit and the power supply match.
•
Only plug the unit into a correctly installed outlet. Ensure that the unit is fused for a rated
fault current of max. 30 mA by means of a fault current protection device.
•
Extension cables and power distributors (e.g. outlet strips) must be suitable for outdoor use
(splash-proof).
•
Protect open plugs and sockets from moisture.
Safe operation
•
Do not use the unit, if electrical lines or the housing are damaged.
•
A damaged connection cable cannot be replaced. Dispose of the unit.
•
Do not carry or pull the unit by its power cable.
•
Never make technical modifications to the unit.
•
Only carry out work on the unit that is described in this manual.
•
Only use original spare parts and accessories.
•
Route lines so that they are protected from damage and nobody can trip over them.
•
Should problems occur, please contact the authorized customer service or OASE.
Intended use
Only use the product described in this manual as follows:
•
For aerating bodies of water.
•
In compliance with the technical specifications.
The following restrictions apply to the unit:
•
Do not use in accessible water basins.
•
Never use the unit with fluids other than water.
•
Do not use in conjunction with chemicals, foodstuff, easily flammable or explosive substances.
•
Never run the unit without water.
•
Do not use for commercial or industrial purposes.
Содержание AquaAir Eco 250
Страница 2: ...A AAR0010 B AAR0011 C AAR0003...
Страница 3: ...3 D EGC0009 E PLX0004 F AAR0004...
Страница 4: ...4 G AAR0005 H AAR0006...
Страница 113: ...BG 113 BG 8...
Страница 115: ...BG 115 30 mA OASE...
Страница 118: ...118 H 5 m Environmental Function Control EFC Environmental Function Control EFC 90...
Страница 119: ...UK 119 UK 8...
Страница 121: ...UK 121 30 OASE...
Страница 124: ...124 H 5 Environmental Function Control EFC Environmental Function Control EFC 90...
Страница 125: ...RU 125 RU 8...
Страница 127: ...RU 127 30 OASE...
Страница 130: ...130 F 2 G H 5...
Страница 131: ...RU 131 Environmental Function Control EFC Environmental Function Control EFC 90...
Страница 132: ...132 CN 8...
Страница 134: ...134 30 mA OASE...
Страница 137: ...CN 137 H 5 m Environmental Function Control EFC EFC 90...
Страница 138: ......
Страница 139: ......
Страница 140: ...OASE GmbH Tecklenburger Stra e 161 48477 H rstel Germany 49 0 5454 80 0 49 0 5454 80 9353 info oase com 87353 12 21...