background image

FISH MATE 2000 / 3000 / 4000

®

Pond Pump · Instructions

www.pet-mate.com

+44 (0)1932 700 001

IMPORTANT SAFETY

INSTRUCTIONS

WARNING - To guard

against injury or death,

basic safety precautions

should be observed,

including the following:

READ AND FOLLOW

ALL SAFETY

INSTRUCTIONS

• Register  your  purchase  on-line

at  www.pet-mate.com/uk

(see

guarantee below).

• All  electrical  work  must  be  carried

out by a competent electrician.

• Check that the voltage label on the

motor  (H)  (see  Fig.  1)  conforms
with your supply voltage.

• The  pump  MUST  be  wired  into  an

R.C.D./G.F.I. 

circuit 

breaker

(maximum  30mA)  and  a  3  AMP
(maximum) fuse. Ensure breaker is
regularly tested in accordance with
manufacturers instructions.

• Connection  to  the  power  supply

should be made through a suitable
dry  weatherproofed  3  pin  plug  or
double  pole  switched  enclosure
with  minimum  3mm  (1/8")  contact
separation in all poles. If product is
hard  wired  to  electrical  supply  this
must  comply  fully  with  the  wiring
regulations of the national and local
electricity authority. The pump must
be  protected  by  a  3  AMP
(maximum) fuse.

• This  appliance  must  be  earthed.  It

is essential that all connections are
securely  made  using  the  following
code:

Brown - Live
Blue - Neutral
Green/Yellow - Earth

• Do not carry or pull the pump using

the supply cord.

• Disconnect  electrical  supply  from

all appliances in the pond including
pumps  and  filters  before  contact
with the pond water or pump.

• Closely  supervise  children  when

near to pond or pond equipment.

• Use  pump  only  for  ponds  -  do  not

use  pump  in  connection  with
swimming pools, showers, etc.

• Use  conduit  approved  by  your

electricity  authority  to  protect
supply  cord  where  damage  from
gardening equipment, children and
animals may occur.

• Discard  pump  if  motor  (H)  shows

visual  defects  (e.g.  cracks  or
swelling).

• The  supply  cord  of  this  appliance

cannot  be  replaced;  if  the  cord  is
damaged  the  appliance  should  be
discarded.

• Do not allow the pump to run dry.
• Do  not  operate  the  pump  in

freezing 

conditions. 

Remove,

disassemble and dry pump if there
is a risk of pump being frozen.

• This  pump  is  provided  with  a

thermal 

cut-out 

switch 

that

temporarily  switches  off  the  pump
in  case  of  overheating.  The  pump
may restart when it has cooled.

SAVE THESE

INSTRUCTIONS

1. PUMP INSTALLATION

For convenience the pump should be positioned within reach
from  the  side  of  the  pond  on  a  solid  platform  (e.g.  paving
slabs)  approximately  250mm  (10")  below  the  pond  surface.
The pump should be at least 200mm (8") below water level
to avoid problems of freezing and low water levels in summer
and no more than 1000mm (40") deep.

Only use pump if completely immersed in water.

A. Waterfall/Filter Only

For use with a pond filter you will often get improved results
with  the  pump  sited  at  the  opposite  end  of  the  pond  to  the
filter return.

The  pump  may  be  connected  to  a  waterfall  or  filter  using
12mm  (1/2"),  19mm  (3/4")  or  25mm  (1")  bore  hose.  Fit
suitable outlet adapter (K) and flow valve (L) into pump outlet
(J).  Insert  adapter  (P)  if  required  and  connect  hose  to
required outlet (see Fig 2c). Insert plug (Q) in unused outlet
and adjust flow using the flow control knob (M).

B. Fountain (and Waterfall/Filter)

Insert fountain components as shown in Fig. 2a (conventional
fountain) / 2b (bell fountain). If required tubes (R) and (T) may
be shortened with a hacksaw. Also fountain (W) may be fitted
directly  to  flow  valve  (N).  For  plume  fountain  do  not  fit  any
parts to tube (T). If required, connect waterfall/filter with hose
to outlet (O) or (P). Alternatively, use blanking plug (Q). The
Fountain  heads  (V)  may  be  unscrewed  anticlockwise  for
cleaning. Adjust  fountain  height/width  using  the  flow  control
(M)  turning  clockwise  for  increased  height.  If  using  the  bell
fountain  you  will  also  need  to  manually  adjust  the  gap
between  parts  (W)  and  (X)  for  the  required  effect.  (Try
starting with approximately 1mm (1/16”) gap.)

2. MAINTENANCE / FAULT FINDING - IMPORTANT SAFETY

INSTRUCTIONS

• Disconnect  electrical  supply  from  pump  before

removing from pond or contacting pond water.

• Do not carry or pull the pump by the cable.

A. ROUTINE MAINTENANCE OR WHEN FLOW FROM YOUR

PUMP  IS  NOTICEABLY  REDUCED  OR  FOUNTAIN
DISPLAY HAS DETERIORATED:

i)

Remove  strainer  cover  (A)  as  shown  by  arrows    1    and

2  in Fig. 1. Clean strainer covers (A) and (H) using a stiff

brush.

ii) Check  and  remove  any  obstruction  to  inlet  on  impeller

cover (B).

iii) Remove and clean fountain head in water with a brush.

iv) Reassemble, taking care to align cut out in top of cover (A)

with grooves (I).

IMPORTANT

If flow is still poor check:

• Flow control (M) is correctly set.

• No blockage or kinks in outlet hose.

B. ONCE  A  YEAR  OR  IF  FLOW  IS  STOPPED  (CHECK

POWER SUPPLY FIRST!):

Completely  disassemble  pump  to  the  component  parts
shown in Fig. 1 as follows:

i)

Disconnect all items fitted to pump outlet (J).

ii) Remove strainer cover (A) as shown in Fig. 1.

iii) Remove  impeller  cover  (B)  by  rotating  anticlockwise.  If

required, pliers can be used as shown in Fig. 3.

iv) Carefully pull out pump impeller assembly (E) then (F).

v) After cleaning of all components:

• Check  cable  and  pump  body  (G)  for  any  damage  or

deterioration and discard pump if suspected faulty.

• Check for wear of impeller (E) on shaft (F) and condition of

seal (C), rubber bushes (D1) and (D2). Replace with new
parts  using  the  appropriate  FISH  MATE  service  kit  as
required.

Carefully reassemble as follows:

vi) Locate shaft (F) into rubber bush (D2) inside pump body (G).

vii) Carefully and slowly slide impeller assembly (E) on to shaft

(F) to avoid damage from the powerful magnet.

viii) Lubricate rubber bush (D1) by immersing in water and then

push halfway on to the end of shaft (F). Align impeller cover
(B)  before  pushing  on  fully  and  rotating  clockwise  into
position.

ix) Refit  front  cover  (A)  taking  care  to  align  cut  out  with

grooves (I).

IMPORTANT - READ BEFORE USE

Pet Mate Ltd. guarantees your product for a period of 3 years from the date of purchase, subject to the registration of your purchase
details on our website www.pet-mate.com/uk within 14 days of purchase. (If you do not have access to a computer, please send details
of your purchase with copy of receipt along with your name and address.) In the event of a fault developing contact Pet Mate customer
services for a returns authorisation number. The guarantee is limited to any defect arising due to faulty materials or manufacture. Any
defective item will be repaired or replaced free of charge at the manufacturer’s discretion, provided that the defect has not been caused
by neglect, misuse or normal wear and tear. The guarantee excludes moving parts and claims arising from frost, accidental damage or
loss of fish. Your statutory rights are not affected.

1

A

C

B

E

F

J

K

I

L

M

O

N

G

H

Q

P

D1

D2

1

2

Downloaded from www.watergardeningdirect.com

All manuals and user guides at all-guides.com

all-guides.com

Отзывы: