- EN -
14
Disposal
Dispose of the unit in accordance with the national legal regulations.
N O T E
Do not dispose of this unit with domestic waste.
•
Render the unit unusable beforehand by cutting the cables and dispose of the unit via the return system
provided for this purpose.
Technical data
Description
Underwater Power Supply 250
Input data (Pri)
Input voltage range
1)
V AC
90 … 264
Max. input current
1)
A
3.5
Starting current for 2 ms at full load and 230 V AC
A
40
Input frequency range
Hz
47 … 63
Power consumption in standby
W
<7
Output data
(Sec)
Output voltage range
1)
V DC
24.25 … 25.75
Max. output current
1)
(no limitation per output)
A
10
Max. power output
1)
W
250
Max. starting current, secondary side for max. 4 ms
A
15
Maximum output/peak power? for max. 4 ms
W
364
Residual ripple
%
≤
1 (U
pp
≤
250 mV)
Setup time at 115/230 V AC
ms
<100
Rise time at 115/230 V AC
ms
<30
Hold-up time at 115/230 V AC
ms
>10
Efficiency
(at rated mains voltage 230 V AC and max. output current)
–
≥
0.92
Power factor
–
≥
0.9
Protection class
–
IP 68
Isolation between the primary/secondary side
–
galvanic
Overvoltage protection (Sec), power pack switches off at
V
≤
33
Overload protection (derating)
–
(→ Derating characteristic curve)
Reset duration after triggering of the overload protection / overvoltage protection
Min
5
High voltage test Test voltage between Pri and Sec
kV AC
≥
4
Test voltage between Pri and PE
kV AC
≥
1.5
Test voltage between Sec and PE
kV AC
≥
500
Insulation resistance between L/N and PE at 500 V AC
M
Ω
>2
Standards complied with
–
EN 61558-1:2005+A1:2009
EN 61558-2-16 + A1:2013
EN 55014-1:2006 + A1:2009 + A2:2011
EN 55014-2:2015
EN 61000-3-2:2014
EN 61000-3-3:2013
Maximum submersion depth
m
4
Permissible water temperature
operation in water, product active
°C
+4 … +35
Permissible water temperature
operation in water, product inactive
°C
+4 … +35
Permissible ambient temperature
operation outside the water, product active
°C
-10 … +40
Permissible storage temperature
(product inactive = disconnected from the power supply)
°C
-20 … +70
Length of power cable
m
10
Dimensions
Length
mm
260
Width
mm
162
Height
mm
77
Weight
kg
5.3
Article number
–
50733
1)
The values were determined after an operating time of 15 minutes and an ambient temperature of +20 °C.
Содержание 50733
Страница 2: ...2 A UWR0008 B PLX0004...
Страница 32: ...17330 12 17...