Issue
Cause
Solution
The unit
is not
performing
Pump power supply not connected
Connect pump to proper power supply, check the supply lines to
make sure the voltage is correct.
Clogged filter
Check and clean filter
Blocked outlet
Check and clean outlet
Inappropriate pump size
Check packaging for proper pump sizing
Pump is not completely submerged
Completely submerge pump in the water.
Insufficient
flow
Pump is clogged
Check and clean pump
Pump is not completely submerged
Completely submerge pump in the water.
Tubing blocked
Clean or replace tubing
Tubing kinked
Eliminate kink, replace tubing if it is damaged
Spillway blocked
Check outlet on spillway for blockage
Excessive flow loss in the tubing due
to friction
Reduce tubing length to reduce frictional loss
Troubleshooting
Maintenance and cleaning
Attention! Dangerous electrical voltage.
Possible consequences:
Death or severe injury.
Protective measures:
Prior to reaching into the water, disconnect the power supply to all units used in the water.
Disconnect the power plug prior to carrying out work on the unit.
●
Before cleaning, always disconnect the pump from the power source.
●
Occasional cleaning of the filter foam will be necessary to ensure the proper functioning of the system. Filter foam
should be removed and washed with clean water when they are visibly soiled. Filter foam should be replaced annually,
ideally in the early spring.
●
The exterior surface of the cover may also need occasional cleaning. Particularly if the openings in the top of the cover
are obstructed. When cleaning the cover use warm water only. Do not use any chemicals that may destroy the
beneficial bacteria.
●
At least once a year the entire system should be disassembled and cleaned thoroughly using clean, warm water. This
should not be done during the warm season as it may take up to 8 weeks to re-establish the environmental balance.
The best time of the year to “breakdown” your system is in early spring before the water temperatures begin to rise.
1.
Start-up
Important:
●
This waterfall spillway is designed to work with a pump. PUMP NOT INCLUDED. The pump switches on automatically
when power connection is established.
1. Switching on the pump:
Connect power plug to the socket.
○
After the pump has been connected the waterfall spillway
will start to fill up and then create waterfall.
2. Switching off the pump:
Disconnect the power plug.