- EN -
13
REMEDY OF FAULTS
Error messages
The 6-character error message is displayed in two alternating parts. First part:
Err
, second part: 3-digit error
number.
Display
Malfunction
Possible cause
Remedy
Err
001
Excess current on
P1
Impeller unit of the flow pump is blocked Remove blockage
Impeller unit soiled
Regularly clean the impeller unit
Impeller unit worn
Replace the impeller unit.
Incorrect flow controller setting
Push the flow controller in the outlet direction
up to the stop (
5
D)
002
No output current
on P1
Flow pump defective
Replace flow pump
StreamMax Pump Controller defective
Replace StreamMax Pump Controller
Plug in socket P1 is not positioned
correctly
Check plug for correct position.
No flow pump connected
Connect flow pump
003
Excess current on
P2
Impeller unit of the flow pump is blocked Remove blockage
Impeller unit soiled
Regularly clean the impeller unit
Impeller unit worn
Replace the impeller unit.
Incorrect flow controller setting
Push the flow controller in the outlet direction
up to the stop (
5
D)
004
No output current
on P2
Flow pump defective
Replace flow pump
StreamMax Pump Controller defective
Replace StreamMax Pump Controller
Plug in socket P2 is not positioned
correctly
Check plug for correct position.
No flow pump connected
Connect flow pump
005
Excess temperature StreamMax Pump Controller heats up
excessively
Set up the unit so that fresh air can always
circulate around the housing.
Ambient temperature too high
•
Set up StreamMax Pump Controller at a cool
location.
•
Reduce ambient temperature
006
Insufficient voltage
•
Power pack defective
•
Incorrect power pack connected
Replace power pack
007
Excess voltage
Possible malfunctions
Malfunction
Cause
Remedy
The unit does not switch on
No supply voltage
Connect the unit to the mains
StreamMax Premium flow pump does
not switch on
Flow pump not connected
Insert plug of the flow pump in socket P1
or P2
StreamMax Pump Controller not config-
ured
Configure StreamMax Pump Controller
Содержание 33919
Страница 1: ...StreamMax Pump Controller...
Страница 2: ...5 2 StreamMax Pump Controller A SMX0021 B SMX0018...
Страница 3: ...5 3 C SMX0022 D SMX0007...
Страница 112: ...BG 112 StreamMax Pump Controller BG 8 30 mA 5 A A...
Страница 117: ...BG 117 OASE GmbH OASE 36 OASE OASE GmbH OASE e CISG OASE GmbH Tecklenburger Stra e 161 D 48477 H rstel OASE...
Страница 118: ...UK 118 StreamMax Pump Controller UK 8 30 5 A...
Страница 123: ...UK 123 OASE GmbH OASE 36 OASE OASE GmbH OASE CISG OASE GmbH Tecklenburger Stra e 161 D 48477 H rstel OASE...
Страница 124: ...RU 124 StreamMax Pump Controller RU 8 30 5 A A...
Страница 129: ...RU 129 OASE GmbH 36 OASE OASE GmbH OASE CISG OASE GmbH 161 D 48477 H rstel OASE...
Страница 130: ...CN 130 StreamMax Pump Controller CN 8 30mA 5 A A...
Страница 135: ...CN 135 CISG Tecklenbur ger Strasse 161 D 48477 H rstel...
Страница 142: ...70332 02 19...