background image

Risk of Injury — Keep children from moving upholstered top.
Never drop or  insert any object into any opening.
Close supervision is necessary when this furnishing is used by, or near, children, invalids or disabled persons. Do not 

leave children alone or allow them to operate the controls. Keep controls out of reach of children. Do not allow children 

to crawl under the table. 
Be certain that the table is completely lowered prior to discharging an ambulatory patient. The patient may lose balance 

and fall. Do not leave clients unattended when table is set at its highest level.
Do Not lift or move the unit without using proper safely procedures or equipment. DO NOT turn the table on its side 

for any reason. To do so could cause damage to the base and will void the warranty. There are no serviceable items that 

require this action. Never lift the table by grasping the table top (or gutter) as the table top (or gutter) is not designed to 

hold the weight of the base and you could damage the table.
When operating the table controls and making any and all adjustments to the table, move hands and feet away from the 

working mechanism of the table. 
Do not put excessive weight or pressure on the QuickLock™ Face Rest. Excessive pressure can cause premature failure 

of the QuickLock™ Face Rest. Do Not extend the dowels of the Face Rest further than 3” (8cm) from the table edge to 

ensure a stable connection.
DO NOT store or place anything under the table that will interfere with the motion of the table.

Maximum Working Load Rating (client and accessories): 400 lbs. / 182 kg.

The table should not be used in any other manner than that described within this manual.  Use of any unnecessary force 

or unauthorized procedures could result in injury to practitioner, client or equipment.

Not using the drape may void the warranty.

DO NOT lift the table by holding the aqueduct drain system. This is not designed to hold the weight of the table. Be 

careful not to place anything in the gutter that might be flushed into the drainage tubing. This could clog the drain pre-

venting free flow of the drain tube.
Do not spray the under side of the table with water or cleaners. Damage to the electrical system may occur.
Do not use high-pressure water to clean the column. Damage to the electrical system may occur.
After unpacking your table, inspect it thoroughly for damage. If you suspect a problem, do not use the table and call our 

customer service department at 717.235.6807.

WARNING

Electrical Shock Hazard. Use this equipment only for its intended use as described in these instructions. Do not use any 

attachment or accessories not recommended by the manufacturer.
To reduce the risk of burns, fire, electric shock or injury to persons:
1.   Do not use outdoors.
2.  Do not operate where aerosol (spray) products are being used or where oxygen is being administered.

2

IMPORTANT SAFETY INSTRUCTIONS

CAUTION

READ AND SAVE THESE INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

Содержание Marina

Страница 1: ...USER MANUAL www oakworks com 717 235 6807 made in the USA with US imported parts OAKWORKS Marina Table...

Страница 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like documen...

Страница 3: ...elling the Table 5 Control Box Battery Use 6 7 Drape Hot Water Bag Use 8 Aqueduct Drain System 8 Quicklock Face Rest 9 Cleaning Disinfection Recommended Cleaners Disinfectants 10 Cleaning Process 11 I...

Страница 4: ...n electrical shock hazard Be sure to observe and comply with all warnings This symbol when used in this manual or on product labels indicates a Protective Earth Ground Terminal This symbol when used i...

Страница 5: ...o ensure a stable connection DO NOT store or place anything under the table that will interfere with the motion of the table Maximum Working Load Rating client and accessories 400 lbs 182 kg The table...

Страница 6: ...nd drain any fluids for treatments Fitted Table drape Hot Water Bag Secures snuggly over the table used with the Hot Water Bag for wet treatments Padding 3 8cm Plush Foam with recessed Aerocel section...

Страница 7: ...ranty The table come complete with one foot control to control height function of the table The Foot Control on the Marina operates all the height positioning at the touch of a pedal Press and hold th...

Страница 8: ...table weighs as much as 242 lbs 110 kg Never lift the table by grasping the table top You could damage the table and the electronics that run the tabletop Four people are required to move the table s...

Страница 9: ...control box found under the table to turn the Control Box OFF To place the battery back into table after charging Push the red Emergency button to turn the control box off Open the Velcro hook and lo...

Страница 10: ...control box is at 75 before it drops to 50 In this way maximum battery life may be achieved If used every day in this man ner a battery should last up to two 2 years It is recommended the battery be...

Страница 11: ...This is not designed to hold the weight of the table Be careful not to place anything in the gutter that might be flushed into the drainage tubing This could clog the drain preventing free flow of th...

Страница 12: ...s adjusting for height and angle and then locking the cam locks into the desired position Important Safety Note Maximum Distance from edge of Table 3 7 6 cm QuickLock Face Rest Insert dowels into Acce...

Страница 13: ...cquer plated metals 2 Clorox Hydrogen Peroxide Disinfectant EPA reg 67619 24 corrosion of metals deterioration of upholstery and wood lacquer leaves a hard to remove residue 3 Virox Accel TB EPA reg 7...

Страница 14: ...ain wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check...

Страница 15: ...l number are located under the table top 12 MODEL NUMBER SERIAL NUMBER MODEL SERIAL NUMBERS MODEL NUMBER DESCRIPTION MA MH WD 31 25 72 PL TT ZZ XX Marina Table Mahogany Trim Wet Dry Table Table Top Wi...

Страница 16: ...orth America Europe Japan Input Service 120 VAC 60 Hz 230 VAC 50 Hz 100 VAC 50 60 Hz Current Draw 7 A 4 A 8 A Voltage Output 24 VDC 24 VDC 24 VDC Electric Shock Protection Class 1 Equipment Class 1 Eq...

Страница 17: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 14...

Страница 18: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 15...

Страница 19: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 16...

Страница 20: ...n Date 03 06 2019 English Printed in USA CONTACT INFORMATION Oakworks Inc 923 East Wellspring Road New Freedom PA 17349 Phone 717 235 6807 FAX 717 235 6798 www oakworks com OAKWORKS Marina Table USER...