background image

DIRECTIONS FOR USE

ADJUSTABLE BREAST COMFORT (ABC) SYSTEM (OPTION)

CAUTION

• 

ABC System Weight Limit - 100 lbs. (45 kg.) Do not sit on the ABC System. 

• 

Do not place foreign objects into the ABC System. Only use as intended. 

• 

For safety of your client, use a cloth sheet between the ABC System and your client.

When turning clients over in the supine 

position, you may use the cushion to level 

during or after their change of position. IT is 

not important that the cushion be completely 

level. As in prone positions, make small 

changes in height and check in with the client.

In Prone positions, for male or female clients when the face rest is in use, lower 

the cushion approximately 3/4” at a time (This is approximately 1 second of 

lowering) and check in with the client regarding their comfort after making the 

change. Incrementally lower the cushion until the client reports they are com-

fortable. Sometimes going back up a little will be preferred. This whole process 

takes no more than 15-20 seconds. After lowering, check headrest position to 

ensure comfort & support. 

NOTE: Breast size is not the only determinate of cush-

ion location. Every person’s comfort spot is different, regardless of breast size.

If you are using the head rest in the 

Supine position, you may use the cush-

ion at relatively high heights to facilitate 

stretching for short periods of time. It is 

not recommended that clients experience 

this position for more than a few minutes.

The OAKWORKS

®

 Adjustable Breast Comfort (ABC) System is designed to lower the pressure on breasts and pectoral 

muscles, allowing the client to relax and create a more comfortable position for their spine. The height of the cushion is 

easily adjusted up and down in small increments by using the hand control. We recommend that the cushion height be 

adjusted in the following ways: 

*Always start with the cushion top level with the top of the table for Prone or Supine Positioning*

PRONE POSITIONING

SUPINE POSITIONING

HEAD REST USE IN SUPINE

13

Содержание Clinician Premiere

Страница 1: ...OAKWORKS Clinician Premiere USER MANUAL www oakworks com 717 235 6807...

Страница 2: ...within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifica tions and the like documen...

Страница 3: ...Comfort ABC System Option 13 Integrated Heated Top Option 14 QuickLock Face Rest Accessory Option 15 Adjustable Side Arm Rests Accessory Option Salon Only 16 Boiance Shelf Support Accessory Option 17...

Страница 4: ...CRIPTION SYMBOL IDENTIFICATION PRODUCT USE DESCRIPTION SYMBOL IDENTIFICATION 1 The Oakworks Clinician Premiere offers a variety of positioning capabilities for massage therapists and spa professionals...

Страница 5: ...ibed in these instructions Do not use attachments not rec ommended by the manufacturer 7 To disconnect turn all controls to the off position then remove plug from outlet 8 Improper connection of the e...

Страница 6: ...or should read these sections carefully Weight Limit client and accessories 500 lbs 227 kg Do not exceed Adjustable Breast Comfort ABC System Weight Limit 100 lbs 45 kg Do not sit on the ABC System On...

Страница 7: ...s equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropri ate outlet that is properly installed and grounded in accordance with all lo...

Страница 8: ...ll powered motions Hand Control All powered motions Table Voltage Options 120V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm...

Страница 9: ...st footrest or optional ABC functions of the table PRODUCT DESCRIPTION Backrest Down Backrest Up Height Down Height Up Footrest Down Footrest Up 9 1 P N 71567 2 P N 71569 2 Backrest DOWN P N 71569 1 P...

Страница 10: ...20V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam Table Weight 170 lbs 77 kg OPTIONS...

Страница 11: ...ht of the table and operate the optional ABC PRODUCT DESCRIPTION CONTROL OPERATIONS FLAT TOP TABLES DOWN UP 8 Height UP P N 71569 1 Height DOWN P N 71569 1 P N 71568 1 Height Down ABC Down ABC UP N 71...

Страница 12: ...le for accessories This product is equipped with an interior 120 volt 60Hz six plug accessory outlet The total electrical load of equipment plugged into this set of outlets is not to exceed 7 amps or...

Страница 13: ...revent unauthorized use Remove the key when not in use and store out of reach of children HYDRAULIC DAILY CYCLING The Clinician Premiere uses hydraulics and hydraulic fluids to adjust the table height...

Страница 14: ...bs 86 kg Four people are required to move the table safely Do not use the table to transport a client DIRECTIONS FOR USE Position at low height TABLE LEVELING INSTRUCTIONS 1 Place the table in the loc...

Страница 15: ...crews If the thumbs screws are on too tight a 3 16 bit can be used 2 Lift top pad off the platform IF THE TABLE HAS A HEATED TOP Unplug the table from the wall outlet and disconnect the wires circled...

Страница 16: ...ometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlydetermi...

Страница 17: ...e 2 controls the lower half of the pad Press both but tons located on the right side of the table in the seat section to turn on both zones and heat the entire top BLINKING LIGHTS If one or both contr...

Страница 18: ...to the bracket until bullet catches are snapped into place To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under...

Страница 19: ...rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS The...

Страница 20: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Страница 21: ...Position Bluetooth Speaker with the magnetic attachment facing up Plug the cord into the side of the speaker and attach it to the bracket CONNECTING TO BLUETOOTH SPEAKER Turn Bluetooth Speaker on by p...

Страница 22: ...e controls again If one or more of the controls still do not work contact Customer Service at 717 235 6807 to arrange replacement IF THE TABLE IS MAKING NOISE DURING HEIGHT ADJUSTMENT CAUTION Disconne...

Страница 23: ...edure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts of...

Страница 24: ...PECTIONS yearly or local standard Check for damage to the power hands control and foot control cables and all visible wiring Visually inspect components for obvious damage that could cause problems du...

Страница 25: ...ted on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 CPSA4EF1T411USXXPW Ser PAD123456 Clinician Premiere 4 Sect SA 4EF 1 T 4 11 US XX...

Страница 26: ...ions 48 2 L x 22 2 W x 14 0 H 122 4cm L x 57 2cm W x 35 6cm H Opening Dimensions Head End 20 0 L x 12 0 H 50 8cm L x 30 5cm H Opening Dimensions Foot End 19 8 L x 12 0 H 50 3cm L x 30 5cm H SPECIFICAT...

Страница 27: ...40 C 20 to 60 RH 98 to 105 kPa Storage Transport 20 29 C to 135 57 C 20 to 95 RH 98 to 105 kPa 24 ELECTRICAL SPECIFICATIONS Designed for North America Europe Input Service 120V 60Hz 12 0 Amps 220V 60H...

Страница 28: ...Phone 717 235 6807 FAX 717 235 6798 www oakworks com USER MANUAL 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 Original Instructions Manual Part Number SPA RA PM 141 Revision Level...