background image

DIRECTIONS FOR USE

TO RAISE THE BACK REST

Raise the back rest by pressing the lever 

under the head section and lifting up to 

the desired height. It is recommended that 

clients take some of their weight off the 

back rest while you lift. 

CAUTION

LIFT-ASSIST BACKREST ADJUSTMENT

Do not sit on the backrest section.

TO LOWER THE BACK REST:

Press the lever under the head section and 

push the back rest down.

LIFT-ASSIST LEG REST ADJUSTMENT

TO RAISE THE LEG REST

Raise the leg rest by pulling the lever on 

the side of the leg section and raise to the 

desired height. It is recommended that 

clients take some of their weight of the leg 

rest while you lift.

TO LOWER THE LEG REST

Pull the lever on the side of the leg  

section and push the leg section down. 

Release the lever once the leg rest is at 

its desired location and the leg section will 

stay in place.

TO CHANGE POSITION OF THE LEG REST LEVER

The leg rest lever can be moved to the opposite side of the table. First, remove the screws from 

the lever and replace the screws. Move the lever to the opposite side of the table. Remove the 

screws that are there and mount the lever.

TO CHANGE POSITION OF THE BACKREST LEVER

The back rest lever can be moved to the opposite side of the back rest by removing the 

screws and relocating the hand lever to the opposite side of the top into the four pre-drilled 

holes.

15

Содержание Clinician Hydraulic Series

Страница 1: ...in the USA with US imported parts Clinician Manual Hydraulic 1 Section Flat Top Clinician Electric Hydraulic 4 Section Lift Assist Salon Top Shown with optional Storage Cabinet Adjustable Breast Comf...

Страница 2: ...d within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like docume...

Страница 3: ...perations ABC Systems Only 11 Clinician Electric Hydraulic Hand Control Operations 12 Clinician Electric Hydraulic Hand Control Operations ABC Systems Only 13 Manual Hydraulic Height Adjustment 14 Lif...

Страница 4: ...ialties On these multifunctional professional tables the practitioner can perform numerous protocols with ease and comfort The Clinician Electric Hydraulic and Manual HydraulicSeries are especially ef...

Страница 5: ...ing administered Do not lift table by the table top This can damage the table When lowering the table make sure there is nothing underneath the table top that can impede motion like stools cabinets ac...

Страница 6: ...s 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam OPTIONS Adjustable Breast Comfort ABC System Hand Control Storage Cabinet...

Страница 7: ...acity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam OPTIONS Adjustable Breast Comfort ABC System Hand Control Stor...

Страница 8: ...0V 60Hz 230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam OPTIONS Adjustable Breast Comfort A...

Страница 9: ...ble Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam OPTIONS Storage Cabinet w Sliding Doors Wood Finishes I...

Страница 10: ...230V 50Hz Table Capacity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam OPTIONS Storage Cabinet w Sliding Doors Woo...

Страница 11: ...ity 500 lbs 227 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6 15 cm Aerocel Foam OPTIONS Storage Cabinet w Sliding Doors Wood Finishes Integrated...

Страница 12: ...s equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all loc...

Страница 13: ...p is not designed for storage DO NOT use this area for holding anything Damage can occur to the table The Oakworks Clinician Electric Hydraulic Tables offer height positioning with electronic ease Ope...

Страница 14: ...lient use a cloth sheet between the ABC System and your client The Oakworks Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client t...

Страница 15: ...d for storage DO NOT use this area for holding anything Damage can occur to the table The Oakworks Clinician Electric Hydraulic Lift Assist Salon Tables offer height positioning with electronic ease O...

Страница 16: ...he ABC System and your client The Oakworks Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfort...

Страница 17: ...e to raise the table to the desired height To lower the table turn the handle counter clockwise To fold handle out of the way rotate until the handle is at its lowest point then pull out slightly Fold...

Страница 18: ...that clients take some of their weight of the leg rest while you lift TO LOWER THE LEG REST Pull the lever on the side of the leg section and push the leg section down Release the lever once the leg...

Страница 19: ...move the table safely Do not use the table to transport a client DIRECTIONS FOR USE Grasp at base end rail at low height range TABLE LEVELING INSTRUCTIONS 1 Place the table in the location where you...

Страница 20: ...little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensure comfort support Once a client s preferences are known the cushion can be b...

Страница 21: ...the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under table cabinet until needed DIRECTIONS FOR USE QuickLockTM FACE REST...

Страница 22: ...ing the table into another outlet Possible causes Two three blinking lights on the control switch indicates that the heating element connector s are not plugged in properly and or damage to the termin...

Страница 23: ...d wipe for cleaners disinfectants to ensure best distribution of disinfectant for the required kill time without leaving excess residue and or overexposing components therefore minimizing the potentia...

Страница 24: ...wet for the disinfectant manufacturer s recommended contact time 4 Throw the used wipe s away and allow the table to dry INSPECTIONS RECOMMENDED REGULAR INSPECTIONS monthly or local standard Check fo...

Страница 25: ...located on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 CFSA4LF1T410USXXPW Ser CFK123456 06 03 2020 Order 785461 Clinician Electric...

Страница 26: ...220 VAC 5 amp 50 60 Hz Current Draw 5 0 amps 2 5 amps Made of Operation Intermittent Operation MAX 2 minutes ON 18 minutes off Intermittent Operation MAX 2 minutes ON 18 minutes off SHIPPING DIMENSIO...

Страница 27: ...THIS PAGE IS INTENTIONALLY LEFT BLANK 24...

Страница 28: ...807 FAX 717 235 6798 www oakworks com USER MANUAL 3034177 CONFORMS TO UL STD 962 Certified to CAN CSA STD C22 2 68 Original Instructions Manual Part Number SPA RA PM 152 Revision level 1 Revision Date...

Отзывы: