background image

WARNINGS & SAFETY INSTRUCTIONS

iv

WARNINGS & IMPORTANT SAFETY INSTRUCTIONS

WARNINGS & IMPORTANT SAFETY INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

(CONT.)

This product is equipped with an interior accessory outlet. The total 

electrical load of equipment plugged  into this set of outlets is not to 

exceed 750 watts.

Close supervision is necessary when this furnishing is used by, or near, 

children, invalids or disabled persons. DO NOT leave children alone or allow 

them to operate the controls. Keep controls out of reach of children. DO NOT 

allow children to crawl into the cabinet or under the table. 

Be certain that the table is completely lowered without any tilt being  

present prior to discharging an ambulatory patient. The patient may  

lose balance and fall. Do not leave clients unattended when table is set at 

its highest level.

The table weighs as much as 200 lbs. DO NOT lift or move the unit 

without using proper safely procedures or equipment. DO NOT turn 

the 

Antigua

 on its side for any reason. To do so could cause damage 

to the base and will void the warranty. There are no serviceable items that 

require this action. Never lift the table by grasping the table top as the 

table top is not designed to hold the weight of the base and you could 

damage the table.

When operating the 

Antigua

 controls and making any and all adjust-

ments to the table, move hands and feet away from the working mecha-

nism of the table. Use care when opening the doors all the way  

so that you do not pinch or injure your fingers. Either arm rest can be 

repositioned to allow a client to get on and off the 

Antigua

 easily. When 

making adjustments to the arm rests make certain that the client’s arms 

are away from the working mechanism.

DO NOT sit on the Arm Rests, the elevated Back Rest or Leg Rest. DO NOT 

place excess weight on the Side Arm Rests. DO NOT use them in assisting 

the client on and off the 

Antigua

DO NOT put excessive weight or pressure on the QuickLock

 Face Rest. 

Excessive pressure can cause premature failure of the QuickLock

 Face 

Rest. Do Not extend the dowels of the Face Rest further than 3” from the 

table edge to ensure a stable connection.

DO NOT use the hand control and the foot control simultaneously as this 

can cause damage to one or both units. 

DO NOT store or place anything on the cabinet hood under the backrest as 

this can cause damage to top and/or hood and will void the warranty.

Maximum Working Load Rating (client and accessories): 550 lbs. (249 kg.)

READ AND 

SAVE THESE  

INSTRUCTIONS

WARNING

WARNING

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

CAUTION

Содержание antigua ATRC

Страница 1: ...igua AVAILABLE WITH ROUND CORNER FLAT TOP BACKREST TOP ELECTRIC FLEX TOP SHOWN HERE Antigua Colonial AVAILABLE WITH ROUND CORNER FLAT TOP BACKREST TOP ELECTRIC FLEX TOP SHOWN HERE STANDARD WOOD DOOR S...

Страница 2: ...bject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc assumes no responsibility for any errors that may appear in this document nor does it make expre...

Страница 3: ...trol pg 5 Hand Control pg 6 Under Table Cabinet pg 7 Side Arm Rests pg 10 QuickLock Face Rest pg 12 Accessory Option Table Extender pg 14 Moving the Antigua pg 14 Section IV Troubleshooting If Table W...

Страница 4: ...d in documentation on this product indicates that the product should be protected from moisture The humidity specifications for Transport Storage are listed on page 18 This symbol when used in documen...

Страница 5: ...ower cord from the power outlet Do not operate the table in standing water Before moving the table disconnect the power cord from the power outlet and secure the electrical cord hand control and foot...

Страница 6: ...ot designed to hold the weight of the base and you could damage the table When operating the Antigua controls and making any and all adjust ments to the table move hands and feet away from the working...

Страница 7: ...terior power source by removing the plug from the outlet When moving the table Turn the accessory controls to the off position disconnect the table from the exterior power source by removing the table...

Страница 8: ...es provided by an electronically adjustable flextop The variety of height and reclining positions align the Antigua top so your client s body is at the optimum level for any number of treatments It fe...

Страница 9: ...ly designed access top allows the seated practitioner total ergonomic access to the client s head region reducing strain and fatigue Four maintenance free hydraulic cylinders are powered by a whisper...

Страница 10: ...Specifications Chart measurements are determined from floor to top of seat pad using standard padding these measurements can be affected by natural material variations in padding published weight may...

Страница 11: ...d wrench or an adjust able wrench Adjust each leg individually in turn by adjusting the height of each leveler foot until the unit rests level and steady This adjust ment will not effect the function...

Страница 12: ...warnings as given in the manual Antigua When operating the Antigua controls be sure to observe all cautions and warnings given in the manual to prevent injury to both operator and client When operatin...

Страница 13: ...vide the most in comfort and ergonomics while staying parallel to the floor no matter what the position Hand Control DIRECTIONS FOR USE Back Rest Control activates backrest down to level position Chil...

Страница 14: ...ything Damage can occur to the table especially when commands that are accessed by the hand control are activated Placing anything on this area will prohibit movement of the backrest and can cause dam...

Страница 15: ...ening Place the screws and the panel in storage in case of future need to reinstall the panel To re install the panel unplug and remove any appliances from the cabinet angle the panel into the opening...

Страница 16: ...ening to allow the cord of the appliance to pass through the cabinet and access the interior outlet thus giving you complete power without the safety hazard and distraction of loose cords in the worki...

Страница 17: ...ted and then actively move it back into the resting position where it will proceed to move automatically with the table top The arm rest is now set and will adjust automatically as you position the cl...

Страница 18: ...notch slip into place Push it in securely and allow the arm rest to rest in the parallel position This resets the arm rest in the proper position for the automatic adjustment feature to be activated...

Страница 19: ...locks into that position The Antigua has outlets at the head of the table for a variety of uses and outlets at the other end that work as well for additional procedures Attaching the QuickLock Face R...

Страница 20: ...her or spread them apart to achieve the most comfortable support for any size face To avoid your client s chin from hitting the spacebar make sure the pad is narrow enough to support their whole face...

Страница 21: ...h your legs beneath you and not with your back Be aware and use proper safe procedures for moving a table of this size to prevent injury to yourself or the table We strongly recommend that a flatbed d...

Страница 22: ...Service at 800 558 8850 to arrange replacement TROUBLESHOOTING The table weighs as much as 200 lbs DO NOT lift or move the unit without using proper safety procedures or equipment DO NOT turn the Anti...

Страница 23: ...olstery fabric involves more than just protecting it from general abrasions cuts and punctures We offer most of the products mentioned above in our therapeutic equipment catalog Therapeutic equipment...

Страница 24: ...ER LEAD PLUGS OAKWORKS Part Voltage ACE Power Cord Plug 7791 120v 60 Hz 3 prong grounded North America 7791 03 220v 50 Hz Continental Plug Europe Italy 7791 04 220v 50 Hz Swiss plug Switzerland 7791 0...

Страница 25: ...sions Opening Dimensions Storage Area 1 Head End Opening Dimensions Storage Area 2 Foot End 20 5 H x 24 5 W x 50 5 L 11 5 H x 20 W x 48 L 12 H X 20 4 L 12 H x19 9 L Cabinet Dimensions 52 1cm L x 62 2c...

Страница 26: ...der QuickLock Face Rest 2 parts 0218 Platform 1 2410 xx Crescent Face Rest Pad 1 7811 xx Side Arm Rest Cushion Right 1 7812 xx Side Arm Rest Cushion Left 1 1732 xx Side Arm Rest Right assembly include...

Страница 27: ...ll liability by OAKWORKS for the product or damages caused by its use The buyer and its customers shall be responsible for proper set up and use of the products as well as any supervision required for...

Страница 28: ...KWORKS Inc 923 East Wellspring Road New Freedom PA 17349 Toll Free USA only 800 916 4613 Phone 717 235 6807 FAX 717 235 6798 www oakworks com Manual Part MMMNST0011 rev 51510 Edition 2 English January...

Отзывы: