MODel nUMbeR & SeRIAl nUMbeR

MODel & SeRIAl nUMbeRS

MODel nUMbeR DeSCRIPTIOn

P C 3 0

 

G 3 x x x x x x 3 M T T

 

x x x x

Procedure Chair

Base

Top - 3 section Back Rest

Table Width

Minimum Table  Height

Table Top  Length

Padding: Comfort Plus

Fabric: TerraTouch

Spaces not used

Options

Model Number

Serial Number

Part No. 70537-7  rev. C

Power Rating:  US  120 V 

60 Hz  

5.8 A

Duty Cycle: MAX 2 minutes ON/18 minutes OFF

Class 1 Equipment

Procedure Tables and Chairs

European Authorized 

Representative:

Emergo Europe

Molenstraat 15

The Hague, 2513 BH 

Netherlands

923 East Wellspring Rd.,  

New Freedom, PA  17349  USA

Phone: 717-235-6807  

www.oakworks.com

3034177

CONFORMS TO:

ANSI/AAMI STD ES60601-1

IEC STD 60601-1-6

Certified to CAN/CSA STD 

C22.2 No. 60601-1

16796025  PC30G32719743MTTZZH8BK

Ser#: PC1565022

PCM 300 Series 27 x 19-35 x 74 3M/TT/XXH8BK

TTSKYBLUE   01/04/2013   Order#:654321

Notes: Sample Product Label

Model Numbers and Serial Numbers always start with a letter.

The model number and serial number are located 

on the seat acrylic on the backside of the chair.

Содержание 300 Series

Страница 1: ...OAKWORKS 300 Series Procedure Chair User MANUAL www oakworksmed com 717 235 6807 made in the USA with US imported parts...

Страница 2: ...ubject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc assumes no responsibility for any errors that may appear in this document nor does it make expr...

Страница 3: ...ixed T Rail 9 Arm Rest Installation and Adjustment 10 Paper Roll Holder Use 10 Procedure Chair Face Rest Crescent 11 T Rail Adapter 11 Power Outlet Use 11 Cleaning Disinfection 12 Inspections Maintena...

Страница 4: ...s indicates a Protective Earth Ground Terminal This symbol when used in this manual or on product labels indicates that the product should be protected from moisture The humidity specifications for Tr...

Страница 5: ...isabled persons The Oakworks Procedure Chair has two lifting columns that raise and lower the chair and three actuators that allow the client to be positioned for both client and therapist comfort Eac...

Страница 6: ...359 lbs 163 kg Options Accessories Retractable Foot Rests Stirrups Pull out from under seat section fully adjustable Adjustable Head Rest OR Large Head Rest 11 long x 10 wide 28 x 25cm adjusting angle...

Страница 7: ...duct is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is prop erly installed and grounded in accordance with...

Страница 8: ...tton does not release pressing and holding any other function button will stop the motion Use any of the top 8 buttons to orient the chair in a favorite position Press and release the MEM button twice...

Страница 9: ...ccessory parts cleaners etc The Multi function Foot Control operates all functions by holding down one button at a time Follow the directions below to access these functions If a function button does...

Страница 10: ...access to the stirrup 3 Fold out to fully open position 2 Grasp Stirrup handle pull out firmly while lifting slightly Pull fully out 4 To rotate stirrup to the desired angle lift slightly and move to...

Страница 11: ...position of the head rest follow these steps The Large head rest is adjusted by using the knob hEAD rEST aNGLE Adjustable Head Rest only Turn knob counter clockwise to unlock the cam Move head rest p...

Страница 12: ...the Leg Rest is fully lowered before using the procedure tray Do not sit or push on the Procedure Tray when extended from the seat Maximum Weight rating of 15 lbs 6 8 kg 2 Pull out the 2 pins on both...

Страница 13: ...r The arm rest is not designed to support the patient s weight to install the arm rests The Arm Rests adjust automatically as the back rest moves to remain parallel to the floor 1 Insert end of arm re...

Страница 14: ...or the Power Outlet is 3 amps Connecting equipment that exceeds this rating will damage the system Only connect low current devices Do not connect an extension cord or power strip to the Power Outlet...

Страница 15: ...to the power hand control or foot control cables Visually inspect components for obvious damage that could cause problems during operation RECOMMENDED PERIODIC INSPECTIONS yearly or local standard Che...

Страница 16: ...e Tables and Chairs European Authorized Representative Emergo Europe Molenstraat 15 The Hague 2513 BH Netherlands 923 East Wellspring Rd New Freedom PA 17349 USA Phone 717 235 6807 www oakworks com 30...

Страница 17: ...ations Designed for North America Europe Input Service 120 VAC 15 amp 60 Hz 230 VAC 10 amp 50 60 Hz Current Draw 5 8 amps 2 9 amps Maximum Momentary Current Consumption 6 0 amps 3 0 amps Voltage Outpu...

Страница 18: ...he electromagnetic environment in which radiated RF disturbances are controlled the customer or the user of the table can help prevent electromagnetic interference by maintaining a minimum distance be...

Страница 19: ...e 2 kV common mode 1 kV differential mode 2 kV common mode Mains power quality should be that of a typical com mercial or hospital environ ment Voltage dips short inter ruptions and voltage variations...

Страница 20: ...RF transmitters as deter mined by an electromagnetic site survey ashould be less than the compliance level in each frequency range b Interference may occur in the vicinity of equipment marked with th...

Страница 21: ...18 this page is intentionally left blank...

Страница 22: ...19 this page is intentionally left blank...

Страница 23: ...20 this page is intentionally left blank...

Страница 24: ...9 Phone 717 235 6807 FAX 717 235 6798 www oakworksmed com made in the USA with US imported parts 3034177 CONFORMS TO ANSI AAMI STD ES60601 1 IEC STD 60601 1 3rd Edition IEC STD 60601 1 2 3rd Edition I...

Отзывы: