background image

Double articulating action provides nearly limitless positioning options with 

the QuickLock Face Rest. The adjustable pad takes pressure off sensitive 

facial areas while providing superb support. The QuickLock Face Rest 

can be used in both prone and supine positioning and folds out of the 

way when not in use. Adjustments are made easily by loosening the 

cam locks, adjusting for height and angle and then locking locks into that 

position. The table has a bracket at the head of the table for a variety of 

uses.

3”

• 

QuickLock Face Rest Weight Limit - 25 lbs (11.3 kg)    

• 

Do not put excessive weight or pressure on the Face Rest. 

• 

Excessive pressure can cause premature failure of the Face Rest.

CAUTION

ATTACHING QUICKLOCK FACE REST:

When attaching the QuickLock Face Rest, slide the frame dowels into the bracket until bullet catches are 

snapped into place. 
To remove the QuickLock Face Rest, gently pull the headrest by the dowels until it comes free. Set it 

safely aside or store it inside the under-table cabinet until needed.

DIRECTIONS FOR USE

QuickLock FACE REST: (ACCESSORY OPTION)

To use the face rest with your clients supine, 

rotate the face rest pad so that the thick part of 

the pad supports your client’s cervical region. 

Adjusting the height and angle of the face rest 

gives your clients perfectly comfortable support.  
The face pad is flexible so that you can bring 

the open ends together or spread them apart to 

achieve the most comfortable support for any 

size face. To avoid your client’s chin from  

hitting the spacebar, make sure the pad is narrow 

enough to support their whole face.
For appropriate cervical flexion, use the cam 

locks to adjust the downward angle of the face 

rest, making sure that the surface of the face rest 

pad at the chin is not lower than the surface of 

the table. 

TIPS FOR GREAT POSITIONING USING THE QUICKLOCK FACE REST:

Pull by dowels 

Pull by dowels 

To remove 

18

Содержание PerformaLift Series

Страница 1: ...tional Adjustable Breast Comfort System 2 Section Lift Assist Backrest Top Shown with optional Adjustable Breast Comfort System USER MANUAL www OAKWORKS com 717 235 6807 made in the with US imported 1...

Страница 2: ...d within this document is subject to change without notice and should not be construed as a commitment by OAKWORKS Inc OAKWORKS Inc encourages requests for technical specifications and the like docume...

Страница 3: ...Comfort ABC Systems Only 12 Moving the Table 13 Leveling the Table 13 Lift Assist Backrest Adjustment 14 Locking Casters Use Option 14 Removing Top Pad 15 Adjustable Breast Comfort ABC System Option...

Страница 4: ...nal protocols require specific positioning for the client While the client receives comfort able relaxing support the comfort level of the therapeutic professional is enhanced by superior ergonom ics...

Страница 5: ...administered Do not lift table by the table top This can damage the table When lowering the table make sure there is nothing underneath the table top that can impede motion like stools cabinets acces...

Страница 6: ...ol All powered motions Hand Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 18...

Страница 7: ...ll powered motions Hand Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm...

Страница 8: ...nd Control All powered motions Table Voltage Options 100V 60Hz 230V 50Hz Table Capacity 550 lbs 250 kg client and accessories Widths 29 74 cm 31 79 cm or 33 84 cm Length 73 185 cm Padding 4 10 cm or 6...

Страница 9: ...is equipped with a cord having an equipment grounding conductor and a grounding pin The pin must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all l...

Страница 10: ...Damage can occur to the table The OAKWORKS PerformaLift Electric Salon Tables offer trendelenburg height backrest and footrest positioning with electronic ease Operate the foot control as shown below...

Страница 11: ...ccur to the table The OAKWORKS PerformaLift Lift Assist Backrest and Flat Top tables offer trendelenburg and height positioning with electronic ease Operate the foot control as shown below to raise or...

Страница 12: ...our client The OAKWORKS Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfortable position for t...

Страница 13: ...ease Operate the hand control as shown below to raise or lower the trendelen burg height backrest or footrest functions of the table MEM1 MEM2 Use any of the top 8 buttons to orient the table in a fav...

Страница 14: ...USE MEM1 MEM2 CAUTION For Lift Assist Backrest Tables Do not sit on backrest section The hood area under the backrest top is not designed for storage DO NOT use this area for holding anything Damage c...

Страница 15: ...lient The OAKWORKS Adjustable Breast Comfort ABC System is designed to lower the pressure on breasts and pectoral muscles allowing the client to relax and create a more comfortable position for their...

Страница 16: ...ot use the table to transport a client DIRECTIONS FOR USE Grasp at base corner At low height range 1 2 13mm Open end Wrench Leveler Foot 1 Place the table in the location where you plan to use it 2 Ro...

Страница 17: ...tion All casters should be locked during use with a client LOCKING CASTERS USE OPTION LOCKING THE CASTERS 1 Place your foot on the end of the casters locking tab 2 Press firmly downward until you hear...

Страница 18: ...crews If the thumbs screws are on too tight a 5 32 bit can be used 2 Lift top pad off the platform IF THE TABLE HAS A HEATED TOP Unplug the table from the wall outlet and disconnect the wires circled...

Страница 19: ...Sometimes going back up a little will be preferred This whole process takes no more than 15 20 seconds After lowering check headrest position to ensurecomfort support NOTE Breastsizeisnottheonlydeterm...

Страница 20: ...standard 120V or 230V wall outlet Ensure heating element connectors 2 are properly connected to control box Check light indicator on front of the unit to ensure power is supplied If not illuminated af...

Страница 21: ...ce To remove the QuickLock Face Rest gently pull the headrest by the dowels until it comes free Set it safely aside or store it inside the under table cabinet until needed DIRECTIONS FOR USE QuickLock...

Страница 22: ...rest at a 60 angle to the backrest 2 Push end all the way into the hole and drop the arm rest into the horizontal position Pull outward to make sure the arm rest is secure TO LEVEL THE ARM RESTS The...

Страница 23: ...head support Note The QuickLock Face Rest is required to use the boiance shelf support system TO INSTALL THE BOIANCE SHELF SUPPORT First install the QuickLock Face Rest at the head end of the table 1...

Страница 24: ...1 MEM2 MEM1 MEM2 1 Locate the Control Box and detach the strain relief by removing the screw holding it in place with a 2 5mm Allen wrench 2 Unplug the foot control from the 3rd control port in the TC...

Страница 25: ...for 10 seconds 3 When no clicking noise is heard from the Control Box during this process the zero limits have been reached 4 Test table to ensure all functions are working properly Note If a non lev...

Страница 26: ...rocedure Because of possible chemical incompatibilities between various cleaning products and bleach utmost care must be taken by the user to avoid potential exposure to harmful or toxic by prod ucts...

Страница 27: ...control and foot control cables and all visible wiring Visually inspect components for obvious damage that could cause problems during operation Check all mechanical functions using the hand control R...

Страница 28: ...rs are located on the underside of the foot section of the table top Model and Serial numbers always start with a letter 16796025 PMXA4EF1T411USXXXX Ser PAD123456 06 03 2020 Order 785461 PerformaLift...

Страница 29: ...AC 10 amp 50 60 Hz 100 VAC 15 amp 50 60 Hz Current Draw 5 0 amps 2 5 amps 5 0 amps Voltage Output to Actuators 24 VDC 24 VDC 24 VDC Electric Shock Protection Class 1 Equipment Class 1 Equipment Class...