TABLE OF CONTENTS 

 

1.

 

INTRODUCTION................................... 1

 

2.

 

SAFETY PRECAUTIONS ..................... 2

 

3.

 

SPECIFICATIONS ................................ 3

 

4.

 

BATTERY INSTALLATION AND 

REPLACEMENT .............................................. 5

 

5.

 

INSERTING AND REMOVING 

OPTIONAL RUBBER ARMOUR ...................... 6

 

6.

 

ASSEMBLING OPTIONAL HANDSFREE 

ACCESORIES .................................................. 7

 

7.

 

SELF TEST ........................................... 8

 

8.

 

CONNECTING A THERMOCOUPLE... 8

 

9.

 

KEY FUNCTIONS ............................... 10

 

10.

 

Display Overview................................. 11

 

11.

 

SELECTING TEMPERATURE SCALE12

 

12.

 

HOLD FUNCTON................................ 12

 

13.

 

MIN AND MAX FUNCTION ................ 13

 

14.

 

AUTO OFF FUNCTION ...................... 13

 

15.

 

CALIBRATION .................................... 13

 

16.

 

CANCELING A FIELD CALIBRATION14

 

17.

 

FIELD CALIBRATION LOCKOUT AND 

RE-ENABLE ................................................... 15

 

18.

 

MAINTENANCE................................... 16

 

19.

 

CLEANING .......................................... 16

 

20.

 

BATTERIES......................................... 16

 

21.

 

TROUBLE SHOOTING ....................... 17

 

22.

 

ACCESSORIES................................... 18

 

23.

 

WARRANTY ........................................ 19

 

24.

 

PRODUCT RETURN ........................... 19

 

25.

 

INNOCAL® CALIBRATION AND 

REPAIR SERVICES  (NORTH AMERICA) .... 20

 

Содержание Type T

Страница 1: ...INSTRUCTION MANUAL Thermocouple Thermometer Type J K T Part of Thermo Fisher Scientific 68X450501 Rev 0 02 08...

Страница 2: ......

Страница 3: ...HERMOCOUPLE 8 9 KEY FUNCTIONS 10 10 Display Overview 11 11 SELECTING TEMPERATURE SCALE12 12 HOLD FUNCTON 12 13 MIN AND MAX FUNCTION 13 14 AUTO OFF FUNCTION 13 15 CALIBRATION 13 16 CANCELING A FIELD CA...

Страница 4: ...erator selection of Celsius or Fahrenheit scale Resolution of 0 1 C F from 199 9 to 999 9 Large backlit LCD with two lines of four digit display Hold feature for temporarily retaining a reading Displa...

Страница 5: ...us atmosphere batteries must only be changed in an area known to be non hazardous CAUTION 1 Do not use or store this instrument in microwave ovens or any abnormally hot or cold areas 2 Weak batteries...

Страница 6: ...418 F to 752 F Out of rangedisplay Resolution 0 1 1 auto ranging 0 1 C F from 199 9 to 999 9 1 C F outside this range Accuracy Below 150 C 238 F 0 25 of reading 1 C 2 F Above 150 C 238 F 0 1 of readi...

Страница 7: ...tery Life Size Three AA 1 5V Alkaline Life 750 hours continuous typical without backlighting Dimensions Without Armor 175mm L X 97mm W X 42mm H With Armor 180mm L X 102mm W X 52mm H Weight with batter...

Страница 8: ...cates 150 hours remaining Selected settings are stored in memory and will remain in memory even after power is turned off or while batteries are being replaced 1 Before changing battery turn instrumen...

Страница 9: ...r armor slide in from the top of meter before pushing the bottom edges of meter down to set it into position Lift up the stand at the back of meter for bench top applications if necessary 2 To remove...

Страница 10: ...7 6 ASSEMBLING OPTIONAL HANDSFREE ACCESORIES You can use the optional magnets and strap in the Hands Free Kit accessories for hands free operations...

Страница 11: ...CTING A THERMOCOUPLE Use the correct thermocouple type for your instrument Using an incorrect thermocouple type will result in erroneous readings Thermocouples are color coded by type using the North...

Страница 12: ...mocouple wiring polarity must be correct If readings decrease as the temperature increases the thermocouple wires may be reversed The red wire is negative for thermocouple wires manufactured in North...

Страница 13: ...ivates Deactivates freezing of the measured reading while in measurement mode min max Activates Deactivates display of the minimum and maximum readings on off light Powers on and shuts off the thermom...

Страница 14: ...rs 2 Bar 550 hours 1 Bar 350 hours Blinking 150 hours CAL Blinks during calibration mode Remains in display indicating field calibration is active HOLD Remain in display during hold mode STABLE Displa...

Страница 15: ...l give you the approximate time required 11 SELECTING TEMPERATURE SCALE Select C or F by pressing the C F key Each time the key is pressed the temperature scale will switch Switching between C and F c...

Страница 16: ...er has a default auto off function of 17 5 minutes To deactivate this function press and hold the min max key while turning on the meter using the on off key A OFF nO will appear indicating that the a...

Страница 17: ...50 F when the temperature reading is stable press the cal key The CAL indicator will stop blinking and the reading will be set to 0 C 32 F The CAL indicator will remain turned on indicating a field ca...

Страница 18: ...tion operation LOCKOUT PROCEDURE 1 Turn the thermometer off 2 Simultaneously press and hold the cal and the C F keys down and momentarily press the on off key Continue to hold the cal and C F keys unt...

Страница 19: ...BY ELECTROSTATIC DISCHARGE CLEAN WITH DAMP CLOTH Do not clean with abrasives or solvents Use mild detergents never immerse nor use excessive fluid 20 BATTERIES If there is no display when the thermome...

Страница 20: ...s FAULT ACTION NO Display Check condition of batteries Check that batteries are inserted properly Display shows Out of range indication Display Shows OPEN No thermocouple connected in the Connector Di...

Страница 21: ...s type J 08517 55 EC TPGLPJ 01M Penetration probe meat semi soft Materials type J 08517 65 EC TPPENJ 01M Surface probe direct contact on Hot surfaces type J 08517 60 EC TPSURJ 01M Clip on probe surfac...

Страница 22: ...s outside the warranty period or those resulting from product misuse or abuse may be invoiced to you 24 PRODUCT RETURN To limit charges and delays contact the seller or Manufacturer for authorization...

Страница 23: ...of customers meet ISO FDA EPA GLPs cGMPs and other quality standards Conformity ISO IEC 17025 2005 accredited NIST Handbook 150 2000 Edition ANSI NCSL Z540 2 1997 NIST Technical Note 1297 ISO 9000 20...

Страница 24: ...ce your instrument We provide you with the documentation you need to meet your most stringent quality requirements for the control of inspection measuring and test equipment Certification includes cer...

Страница 25: ...send you an automatic reminder when it is time to recalibrate your instrument Are your calibration certificates good enough InnoCal surpasses the competition by providing the most complete certificat...

Страница 26: ...eters 270 to 2316 C 454 to 4200 F Probes Systems 80 to 1000 C 112 to 1832 F Actual range is dependent on type of probe MM 17000 10 MM 17001 10 MM 17002 10 InnoCal The Choice of Quality 866 InnoCal 866...

Страница 27: ......

Страница 28: ...tor or visit our web site listed below OAKTON Instruments P O Box 5136 Vernon Hills IL 60061 USA Tel in U S 888 462 5866 Tel outside U S 1 847 549 7600 Fax 1 847 247 2984 Website www 4oakton com E mai...

Отзывы: