- 9 - 

7. CONNECTING 

THERMOCOUPLE 

 

Use the correct thermocouple type for 

your instrument setting. Using an 

incorrect thermocouple type will result in 

erroneous readings. Thermocouples are 

colour coded by type  using the North 

American ANSI Colour Code as follows: 

 

TYPE COLOR

 

Black 

K Yellow 
T Blue 

E Purple 

Thermocouple connectors have one wide 

blade and one narrow blade. Do not force 

connector in backwards. Connect 

thermocouples to receptacles at top of 

instrument as shown in the following 

illustration. 

 

 

 

 

Содержание Temp-100

Страница 1: ...Instruction Manual Temp 100 and Temp 300 Dual Input Thermocouple Datalogging Thermometer 68X518203 Rev 0 07 09...

Страница 2: ......

Страница 3: ...1 9 DISPLAY OVERVIEW 12 10 MEASUREMENT MODE 13 11 HOLD FUNCTON 14 12 MIN MAX and AVE FUNCTION 14 13 DATA LOGGING 14 14 SETUP MODE 15 15 GENERAL SETUP SCREEN 16 16 CALIBRATION SCREEN 18 17 ALARMS SCREE...

Страница 4: ...000 on Temp 300 USB output Temp 300 only Differential temperature measurements Operator selection of Celsius or Fahrenheit scale Resolution of 0 1 C F from 199 9 to 999 9 Large backlit LCD with two li...

Страница 5: ...us atmosphere batteries must only be changed in an area known to be non hazardous CAUTION 1 Do not use or store this instrument in microwave ovens or any abnormally hot or cold areas 2 Weak batteries...

Страница 6: ...to 400 C Type T 418 F to 752 F 250 C to 1000 C Type E 418 F to1832 0 C to 1768 C Type R 300 only 32 F to 3214 F 0 C to 1768 C Type S 300 only 32 F to 3214 F 250 C to 1300 C Type N 300 only 418 F to 23...

Страница 7: ...acklit Dot matrix 50mm X 37 2mm Data Logging Temp 100 1000 points Temp 300 2000 points Logging Interval 1 sec to 60 min Min Max Avg Function Yes Auto Off adjustable time Enable Disable option availabl...

Страница 8: ...ontinuous typical without backlighting Dimensions Without Armor 175mm L X 97mm W X 42mm H With Armor 180mm L X 102mm W X 52mm H Weight with batteries Without Armor 267g With Armor 362g Ingress protect...

Страница 9: ...ry annunciator indicates that the batteries should be replaced immediately Selected settings are stored in memory and will remain in memory even after power is turned off or while batteries are being...

Страница 10: ...r armor slide in from the top of meter before pushing the bottom edges of meter down to set it into position Lift up the stand at the back of meter for bench top applications if necessary 2 To remove...

Страница 11: ...8 6 ASSEMBLING OPTIONAL HANDSFREE ACCESORIES You can use the optional magnets and strap in the Handsfree Kit accessories for hands free operations...

Страница 12: ...neous readings Thermocouples are colour coded by type using the North American ANSI Colour Code as follows TYPE COLOR J Black K Yellow T Blue E Purple Thermocouple connectors have one wide blade and o...

Страница 13: ...ed wire is negative for thermocouple wires manufactured in North America If no probe is connected the display will read open Thermocouples are sensitive at the tip or measuring junction When taking me...

Страница 14: ...F1 Step through Min Max and Avg readings F2 Choose probe T1 T2 or T1 T2 F3 Toggle between menu and measure mode hold Freeze display on off light Turns meter on and off press and hold for 3 seconds to...

Страница 15: ...surement data 1 HOLD Active 2 Data Logging is Active 3 Alarm Enabled channel in alarm indicated T1 or T2 or T1 T2 4 MAX MIN AVG of Secondary channel if MIN MAX AVG activated 5 MAX MIN AVG of Primary c...

Страница 16: ...n the primary display and for input two in the secondary display Pressing the F2 key will toggle primary display through input one T1 input two and the delta T1 T2 values Pressing the F1 key initiates...

Страница 17: ...e that occurs The minimum and maximum values are sensed and automatically stored To exit and clear this function press the F3 to access the Menu functions See the Clear Reset menu section for more det...

Страница 18: ...e meter key pad to scroll through options To enter a setup screen press Select F1 key To return to measurement mode press Meas F3 key Following menu options are listed 1 General Setup 2 User field cal...

Страница 19: ...measurement units time and date Press F1 to indicate you want to change the setting of the current parameter or recall or log to move to the next parameter Press recall or log to change the options P...

Страница 20: ...the second page you can set auto off time line frequency and password This screen below is used to reset change password In the event if uses forget his her password 5586 can be used to reset to a new...

Страница 21: ...form a field calibration to obtain specified meter accuracy Use the field calibration feature to improve thermometer probe accuracy or to compensate for thermocouple drift Before go into the calibrati...

Страница 22: ...ibration method by pressing F1 and the or keys Then select the channel you with to calibrate the or keys Offset Calibration Use the or keys to adjust the value to match known temperature standard Pres...

Страница 23: ...ys to adjust the value to match known temperature standard Press F1 to accept Then move to second temperature point using the or keys and repeat Match Calibration Use the or keys to adjust the value t...

Страница 24: ...21 17 ALARMS SCREEN Disable or enable the alarm for individual probe by pressing recall or log and F1 to accept Increase or decrease individual limit by pressing recall or log...

Страница 25: ...l If it is auto logging using recall or log to set time interval Its range is from 0min to 60min Button Page1 will appear only in Temp 300 Data Transfer from Meter to Computer Model 300 only Please re...

Страница 26: ...is establish with PC press the Start button to download data from Meter to PC using HyperTerminal 19 CALIBRATION REPORT SCREEN The Calibration report will show the time and date along with results of...

Страница 27: ...24 20 CLEAR RESET SCREEN Press F1 to choose which data you want to clear or reset For calibration logged data and reset all you will have to enter the password to proceed Default Password is 9900...

Страница 28: ...BY ELECTROSTATIC DISCHARGE CLEAN WITH DAMP CLOTH Do not clean with abrasives or solvents Use mild detergents never immerse nor use excessive fluid 23 BATTERIES If there is no display when the thermome...

Страница 29: ...s FAULT ACTION NO Display Check condition of batteries Check that batteries are inserted properly Display shows Out of range indication Display Shows OPEN No thermocouple connected in the Connector Di...

Страница 30: ...EC TPGLPJ 01M Penetration probe meat semi soft Materials type J 08517 65 EC TPPENJ 01M Surface probe direct contact on Hot surfaces type J 08517 60 EC TPSURJ 01M Clip on probe surface contacts Electr...

Страница 31: ...s outside the warranty period or those resulting from product misuse or abuse may be invoiced to you 27 PRODUCT RETURN To limit charges and delays contact the seller or Manufacturer for authorization...

Страница 32: ...tomers meet ISO FDA EPA GLPs cGMPs and other quality standards Conformity ISO IEC 17025 2005 accredited NIST Handbook 150 2000 Edition ANSI NCSL Z540 2 1997 NIST Technical Note 1297 ISO 9000 2000 Fast...

Страница 33: ...ce your instrument We provide you with the documentation you need to meet your most stringent quality requirements for the control of inspection measuring and test equipment Certification includes cer...

Страница 34: ...send you an automatic reminder when it is time to recalibrate your instrument Are your calibration certificates good enough InnoCal surpasses the competition by providing the most complete certificat...

Страница 35: ......

Страница 36: ...For more information on OAKTON Instruments Products please contact your nearest distributor or visit our web site listed below OAKTON Instruments P O Box 5136 Vernon Hills IL 60061 USA Tel in U S 888...

Отзывы: