OAKTON “Singles” calibration solution pouches  

20/box.

±0.01 pH accuracy at 25°C. Shpg wt 1.1 lb (454 g) per box.

WD-35653-00 Deionized rinse water solution pouches, 

WD-35653-01 pH 4.01 “Singles” buffer solution pouches

WD-35653-02 pH 7.00 “Singles” buffer solution pouches

WD-35653-03 pH 10.00 “Singles” buffer solution pouches

WD-35653-04 Assortment pack, 

5 ea. deionized water, pH 4.01, pH 7.00, and pH

10.00 solution pouches.

Consult your OAKTON

®

Distributor for a complete selection of pH and ORP elec-

trodes, solutions and accessories. Ask for bulletin Accessories A1.

NOTE:  Remember to check the temperature calibration when replacing the ATC
probe.  See section 4.2, "Temperature calibration" (page 9).

10. Warranty

OAKTON warrants this meter to be free from significant deviations in material and
workmanship for a period of one year from date of purchase. OAKTON warrants
this probe to be free from significant deviations in material and workmanship for a
period of six months from date of purchase. If repair or adjustment is necessary and 
has not been the result of abuse or misuse within the warrantied time period, please
return—freight prepaid—and correction will be made without charge. OAKTON
alone will determine if the product problem is due to deviations or customer misuse.

Out-of-warranty products will be repaired on a charge basis.

11. Return of items

Authorization must be obtained from your OAKTON distributor before returning
items for any reason. When applying for authorization, please include data regard-
ing the reason the items are to be returned. For your protection, items must be care-
fully packed to prevent damage in shipment and insured against possible damage or
loss. We will not be responsible for damage resulting from careless or insufficient
packing. A restocking charge will be made on all unauthorized returns.

NOTE

: We reserve the right to make improvements in design, construction, and

appearance of products without notice.

Содержание pH 5+

Страница 1: ...DISTRIBUTED BY 00702 41 OPERATING INSTRUCTIONS OAKTON WD 35613 00 01 10 11 pH 5 and pH 6 Acorn Series Meters Printed in the U S A 8 98 pH 6 Acorn series pH mV C Meter ON OFF CAL HOLD ENTER MODE INC...

Страница 2: ...ng the Meter on 7 4 Calibration 8 10 4 1 pH Calibration 8 9 4 2 Temperature Calibration 9 4 3 Millivolt mV Calibration 10 5 Measurement 11 5 1 Taking Measurements 11 5 2 HOLD feature 11 6 Electrode Ca...

Страница 3: ...ectrode maintenance error messages and troubleshooting This part of the manual also includes the Specifications Accessories Warranty and Return of Items section 2 Display and Keypad Functions The Acor...

Страница 4: ...e electrode s connector push together and twist the electrode connector 1 2 turn until it clicks into place To remove simply rotate the connector counter clockwise until it unlocks and slide the conne...

Страница 5: ...to indicate CAlibration See figure The display will then show the current noncalibrated reading blinking while in calibration mode See figure 5 Allow the reading to stabilize The meter auto matically...

Страница 6: ...le value and then loops back to the minimum allowable value 4 Press ENTER key to confirm calibration The LCD displays CO and the meter then reverts to measurement mode 5 Measurement Taking Measurement...

Страница 7: ...heat a diluted KCl solution for 60 80 C Place the sens ing part of the electrode into the heated solution for about 10 minutes Allow the electrode to cool in some unheated KCl solution Protein deposi...

Страница 8: ...e and temperature probe WD 35613 11 Additional pH 6 Series Acorn Meter pH mV C with temperature probe electrode not included Accessories WD 35606 80 Protective Rubber Boot encases meter in sturdy rubb...

Страница 9: ...to be free from significant deviations in material and workmanship for a period of six months from date of purchase If repair or adjustment is necessary and has not been the result of abuse or misuse...

Страница 10: ...19 18...

Отзывы: