Work Order #
Orifice # (Main)
BTU Rating
Orifice # (OTHER)
Serial #
Leak Test
Model #
Burn Test
Air Shutter
Gas Type
Inspector:
LP - NAT
MANUFACTURER’S USE ONLY - QUALITY CHECK
COM0580
FIGURE 1
LP 47,500 / NG 56,000
Date
Follow steps 1 – 5 shown above.
THE CONVERSION SHALL BE CARRIED
OUT BY A MANUFACTURER’S
AUTHORIZED REPRESENTATIVE, IN
ACCORDANCE WITH THE REQUIREMENTS
OF THE MANUFACTURER, PROVENCIAL
OR TERRITORIAL AUTHORITIES HAVING
JURISDICTION AND IN ACCORDANCE WITH
THE REQUIREMENTS OF THE
CAN/CGA-B149.1 OR CAN/CGA-B149.2
INSTALLATION CODES.
After conversion follow Operating
Instructions found on Page 11.
Casual Fireside Fire Pits Are
Suitable For Installation from
0 - 4,500 ft. Without Modification.
Carefully detach the flex line connector hose attached to the orifice holder (Figure # 1) and unscrew the orifice holder
from the burner pipe (Figures #1 and # 2).
#45
3.
Remove the orifice from the holder (Figure # 2 ) and replace it with the proper sized one for your gas requirement.
Propane requires the smaller orifice.
4.
If you are converting from propane (LP) gas to natural gas, install the air shutter sleeve so that the air intake holes are
closed (Figure #2). For Propane gas, remove the air shutter so that the air intake holes are open (Figure #1).
After
the unit is assembled for use, it is requires a "leak check" test on all connections are before placing the unit
in operation.
5.
IT IS NECESSARY TO ATTACH THE LABEL OR RATING PLATE INCLUDED WITH THE CONVERSION KIT TO
CLEARLY INDICATE THE FIELD CONVERSION.
X
#25 / COM0580CK
Page 12
FIGURE 2
CONVERTING YOUR FIRE PIT TO A DIFFERENT GAS TYPE
1.
MAKE SURE THAT THE GAS SUPPLY TO THE FIRE PIT (AND ANY NEARBY ELECTRICAL
SOURCES/APPLIANCES) ARE SHUT OFF.
2.
After The Unit Is Converted, it Must Be
Tested to Verify the Inlet and Manifold
pressures are as specified on Page 3.
Additionally, the authorized representative
must verify that the input rate of the
converted appliance match the rate listed
below.
Orifice
Orifice
Holder
Burner
When
converting to
natural
gas,
the
air
shutter
sleeve MUST
be
installed
over
the
burner
pipe.
Flex
Line
Connector Hose
Burner
Orifice
Holder
Flex
Line
Connector Hose
Orifice
Air
Intake hole
open
for
LP
Gas