UM10468
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2011. All rights reserved.
User manual
Rev. 1 — 30 August 2011
4 of 27
NXP Semiconductors
UM10468
SSL2108X buck evaluation board
2. Safety
warning
This reference board is connected to a high AC voltage (up to 250 V). Avoid touching the
demo board during operation. An isolated housing is obligatory when used in
uncontrolled, non-laboratory environments. Galvanic isolation of the mains phase using a
fixed or variable transformer (Variac) is always recommended. These devices are
recognized by the symbols shown in
3. Specification
[1]
Refer to
for more detailed information.
a. Isolated
b. Not isolated
Fig 1.
Variac isolation symbols
019aab173
019aab174
Table 2.
Specifications for the reference board
Parameter
Value
Comment
AC line input voltage
SSL21081 and SSL21082
85 V (AC) to 138 V (AC)
optimized for 100 V (AC)
SSL21083 and SSL21084
230 V (AC)
optimized for 100 V (AC)
Output voltage (V
LED
)
SSL21081 and SSL21082
20 V to 70 V
optimized for 60 V
SSL21083 and SSL21084
20 V to 140 V
optimized for 120 V
Output current (I
LED
)
SSL21081
95 mA, 70 mA, 38 mA
adjust using jumpers J7A, J8A, J9A
SSL21082
160 mA, 125 mA, 105 mA
adjust using jumpers J7A, J8A, J9A
SSL21083
55 mA, 35 mA, 18 mA
adjust using jumpers J7A, J8A, J9A
SSL21084
80 mA, 69 mA, 53 mA
adjust using jumpers J7A, J8A, J9A
Maximum LED output power (P
o(LED)
)
SSL21081 and SSL21083
6 W
optimized for 6 W using dedicated loads
SSL21082 and SSL21084
15 W
optimized for 10 W using dedicated loads
Switching frequency
Nominal switching frequency
(f
sw(nom)
)
100 kHz
-
Board dimension (L
W
H)
SSL21081, SSL21082, SSL21083
and SSL21084
70 mm
60 mm
23 mm
maximum footprint
Temperature
Operating temperature
40
C to +100
C
-