Software
Migration in IAR Embedded Workbench
Migration Guide from MKW36Z512xxx4 to MKW35Z512xxx4, User's Guide, Rev. 1, 06/2019
10
NXP Semiconductor
6.
Select the heart rate sensor in the workspace and press Alt+F7 to open project options window.
In C/C++ Compiler/Preprocessor window, rename the paths related to MKW36Z folders to
MKW35Z folders modifying a 5 number instead of 6 in the additional include directories text
box. The results must look similar as shown below:
$PROJ_DIR$/middleware/wireless/framework_5.4.2/LowPower/Interface/MKW3
5
Z
$PROJ_DIR$/../../../../../../../devices/MKW3
5
Z4/drivers
$PROJ_DIR$/../../../../../../../middleware/wireless/framework_5.4.2/DCDC/Interface/MKW3
5
Z
$PROJ_DIR$/../../../../../../../middleware/wireless/framework_5.4.2/XCVR/MKW3
5
Z4
$PROJ_DIR$/../../../../../../../devices/MKW3
5
Z4
$PROJ_DIR$/../../../../../../../devices/MKW3
5
Z4/utilities
Figure 11. Updating the MKW35 files
7.
Rename the CPU_MKW36Z512VHT4 macro as CPU_MKW3
5
Z512VHT4 and delete
FRDM_KW36 and FREEDOM macros in defined symbols text box. Click the OK button.
Содержание MKW35Z512xxx4 Series
Страница 27: ......