Physical Layer Interface Controller (PLIC)
MCF5272 ColdFire
®
Integrated Microprocessor User’s Manual, Rev. 3
Freescale Semiconductor
13-13
13.3.2
Super Frame Sync Generation
shows the generation of the 2-KHz super frame sync. The choice of either FSC0 or FSC1 is
possible using P1CR[FSM]. This allows either the port 0 or port 1 timing to be used to generate the 2-KHz
super frame sync interrupt. The SFSC block then divides this accordingly. When P1CR[FSM] is set, FSC1
is the source of the super frame sync. In case P1CR[MS] is 0 (that is, port 1 is in slave mode), the interrupt
is ultimately driven by an external source. In case the M/S bit is 1 (that is, port 1 is in master mode), FSC1
ultimately comes from port 0.
13.3.3
Frame Sync Synthesis
illustrates the relationships between the various frame sync clocks. DFSC1 is generated
through programmable delay 1 referenced to DFSC0. DFSC2 and DFSC3 are generated through
programmable delays 2 and 3 referenced to DFSC1. Note well the following:
•
P0SDR settings affect DFSC[0–3]
•
P1SDR settings affect DFSC[1–3]
•
P2SDR settings affect only DFSC2
•
P3SDR settings affect only DFSC3
13.4
PLIC Register Memory Map
lists the PLIC registers with their offset address from MBAR and their default value on reset.
Table 13-1. PLIC Module Memory Map
MBAR
Offset
[31:24]
[23:16]
[15:8]
[7:0]
0x0300
Port0 B1 Data Receive (P0B1RR)
0x0304
Port1 B1 Data Receive (P1B1RR)
0x0308
Port2 B1 Data Receive (P2B1RR)
0x030C
Port3 B1 Data Receive (P3B1RR)
0x0310
Port0 B2 Data Receive (P0B2RR)
0x0314
Port1 B2 Data Receive (P1B2RR)
0x0318
Port2 B2 Data Receive (P2B2RR)
0x031C
Port3 B2 Data Receive (P3B2RR)
0x0320
Port0 D Data Receive
(P0DRR)
Port1 D Data Receive
(P1DRR)
Port2 D Data Receive
(P2DRR)
Port3 D Data Receive
(P3DRR)
0x0328
Port0 B1 Data Transmit (P0B1TR)
0x032C
Port1 B1 Data Transmit (P1B1TR)
0x0330
Port2 B1 Data Transmit (P2B1TR)
0x0334
Port3 B1 Data Transmit (P3B1TR)
0x0338
Port0 B2 Data Transmit (P0B2TR)
0x033C
Port1 B2 Data Transmit (P1B2TR)
Содержание MCF5272 ColdFire
Страница 2: ......
Страница 38: ...MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 xxxviii Freescale Semiconductor...
Страница 60: ...MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 lx Freescale Semiconductor...
Страница 118: ...Local Memory MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 4 16 Freescale Semiconductor...
Страница 160: ...Debug Support MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 5 42 Freescale Semiconductor...
Страница 258: ...Ethernet Module MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 11 40 Freescale Semiconductor...
Страница 296: ...Universal Serial Bus USB MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 12 38 Freescale Semiconductor...
Страница 360: ...Timer Module MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 15 6 Freescale Semiconductor...
Страница 406: ...General Purpose I O Module MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 17 12 Freescale Semiconductor...
Страница 474: ...Bus Operation MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 20 26 Freescale Semiconductor...
Страница 528: ...List of Memory Maps MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 A 12 Freescale Semiconductor...
Страница 540: ...Index MCF5272 ColdFire Integrated Microprocessor User s Manual Rev 3 Index 10 Freescale Semiconductor...
Страница 543: ...blank...