UM11029
All information provided in this document is subject to legal disclaimers.
© NXP Semiconductors N.V. 2017. All rights reserved.
User manual
Rev. 1.0 — 16 June 2017
313 of 515
NXP Semiconductors
UM11029
Chapter 18: LPC84x SPI0/1
Section 18.7.2.3 “Transfer_delay”
Table 338. SPI Delay register (DLY, addresses 0x4005 8004 (SPI0), 0x4005 C004 (SPI1)) bit description
Bit
Symbol
Description
Reset
value
3:0
PRE_DELAY
Controls the amount of time between SSEL assertion and the beginning of a data
transfer.
There is always one SPI clock time between SSEL assertion and the first clock edge.
This is not considered part of the pre-delay.
0x0 = No additional time is inserted.
0x1 = 1 SPI clock time is inserted.
0x2 = 2 SPI clock times are inserted.
...
0xF = 15 SPI clock times are inserted.
0
7:4
POST_DELAY
Controls the amount of time between the end of a data transfer and SSEL
deassertion.
0x0 = No additional time is inserted.
0x1 = 1 SPI clock time is inserted.
0x2 = 2 SPI clock times are inserted.
...
0xF = 15 SPI clock times are inserted.
0
11:8
FRAME_DELAY
If the EOF flag is set, controls the minimum amount of time between the current frame
and the next frame (or SSEL deassertion if EOT).
0x0 = No additional time is inserted.
0x1 = 1 SPI clock time is inserted.
0x2 = 2 SPI clock times are inserted.
...
0xF = 15 SPI clock times are inserted.
0
15:12 TRANSFER_DELAY Controls the minimum amount of time that the SSEL is deasserted between transfers.
0x0 = The minimum time that SSEL is deasserted is 1 SPI clock time. (Zero added
time.)
0x1 = The minimum time that SSEL is deasserted is 2 SPI clock times.
0x2 = The minimum time that SSEL is deasserted is 3 SPI clock times.
...
0xF = The minimum time that SSEL is deasserted is 16 SPI clock times.
0
31:16 -
Reserved. Read value is undefined, only zero should be written.
NA