18.1 How to read this chapter
Remark:
The ADCHS block is only available on the LPC4370.
18.2 Basic configuration
The GIMA is configured as follows:
•
See
for clocking and power control.
•
The GIMA is reset by the BUS_RST (reset #8 ). Do not reset the GIMA during normal
operation
•
The GIMA outputs are connected to the timer, SCT, ADC, and event router
peripherals (see
•
To configure the GIMA inputs for the timers and SCT, set the CTOUTCTRL bit in
CREG6 (
). This bit controls whether the SCT outputs are ORed with the
timer match outputs or whether the SCT outputs only are used.
18.3 General description
The Global Input Multiplexer Array (GIMA) connects events to various event triggered
peripherals such as the ADCs, the SCT, or the timers.
Each output of the GIMA is connected to a peripheral function (for example, a timer
capture input or an ADC conversion trigger input) and configured through one register,
which selects the event triggers and configures the clock synchronization.
For example, an ADC conversion can be triggered on either an SCT output or a timer
match output. To select the trigger event, use GIMA output 28 which is connected to the
ADC0 and ADC1 start0 conversion inputs. The corresponding GIMA output register
ADCSTART0_IN selects SCT output 15 or the match output 0 of timer 0 as conversion
triggers (see
).
18.3.1 GIMA event input selection
Events that can trigger a peripheral function (e.g. an ADC conversion or a timer capture)
can be selected from the following sources:
•
Timer capture pins
•
SCT input pins
•
Timer0/1/2/3 match outputs
UM10503
Chapter 18: LPC43xx/LPC43Sxx Global Input Multiplexer
Array (GIMA)
Rev. 2.1 — 10 December 2015
User manual
Table 207. GIMA clocking and power control
Base clock
Branch clock
Maximum
frequency
Clock to GIMA register interface
BASE_M4_CLK
CLK_M4_BUS
204 MHz