UM10360_0
© NXP B.V. 2009. All rights reserved.
User manual
Rev. 00.06 — 5 June 2009
511 of 808
NXP Semiconductors
UM10360
Chapter 25: LPC17xx Motor Control PWM
Dead-time counter
When the a channel’s DTE bit is set in MCCON, the dead-time counter delays the
passive-to-active transitions of both MCO outputs. The dead-time counter starts counting
down, from the channel’s DT value (in the MCDT register) to 0, whenever the channel’s A
or B output changes from active to passive. The transition of the other output from passive
to active is delayed until the dead-time counter reaches 0. During the dead time, the
MCOA and MCOB output levels are both passive.
shows operation in edge
aligned mode with dead time, and
shows center-aligned operation with
dead time.
Fig 122. Edge-aligned PWM waveform with dead time, POLA = 0
Fig 123. Center-aligned waveform with dead time, POLA = 0
MAT
MAT
LIM
LIM
0
POLA = 0
timer reset
timer reset
MCOA
MCOB
active
active
passive
passive
passive
passive
active
active
DT
DT
DT
DT
MAT
MAT
LIM
LIM
0
0
POLA = 0
MCOA
MCOB
active
active
passive
passive
passive
passive
active
active
DT
DT
DT