Installing the Software and Setting up the Hardware
KT34FS6407-34FS6408UG User’s Guide Rev. 1.0 8/2015
24
Freescale Semiconductor, Inc.
6.2
Configuring the Hardware
shows the setup required to use KIT34FS6407EVB or KIT34FS6408EVB.
Figure 8. Evaluation Board Setup
6.2.1
Step-by-step Instructions for Setting Up the Hardware
Set up the KIT34FS6407EVB/KIT34FS6408EVB hardware and software as follows:
1. Install the software GUI (either SPIGen or MC3390X_GUI) on your computer (See
Section 6.1 "Installing the GUI Software"
.)
2. Flip the KITUSBSPIDGLEVME Interface Dongle over and mount its IO Port connector to Connector J24 on the evaluation board.
3. Connect a USB cable from the Interface Dongle to the PC.
4. Set the EVB jumpers and switches as needed. Refer to
5. Select Debug or Normal mode with jumper J17.
6. Attach loads to connector JP1 as needed.
7. Attach DC power supply on J3 or J7 (maximum voltage: 40 V).
8. Switch SW1 to supply the board.
9. If SW2 switches are ON and V
BAT
is set correctly, then V
PRE
, V
CCA
, V
AUX
, CAN_5 V LEDs should turn ON. V
BAT
value is
dependent on V
PRE
configuration. In Buck mode, it must be 8.2 V min. FS0B LED should turn ON (J13 / J30 must be plugged).
KITUSBSPIDGLEVME
KIT34FS6407EVB/34FS6408EVB
Power Supply
USB Cable
(+)
(-)
KIT34FS6407EVB/KIT34FS6408EVB