NXP Semiconductors
AN12397
EdgeLock
TM
SE050 Quick start guide with i.MX6UltraLite
AN12397
All information provided in this document is subject to legal disclaimers.
© NXP B.V. 2019. All rights reserved.
Application note
Rev. 1.2 — 17 December 2019
534512
15 / 21
5 Using SE050 ssscli tool
In
we have prepared the hardware setup and the software setup
respectively. To validate that the whole process was done correctly and that your setup is
fully operational, we are going to run the
ssscli
tool. To start the
ssscli
tool, send the
commands shown in
:
1. Open the connection:
Send: >
ssscli connect se050 t1oi2c none
2. Send the reset command:
Send: >
ssscli se05x reset
Figure 15. Start the ssscli tool
Note
:
If you see the following message: WARNING:sss.connect:Session already
open, close current session first message as shown in
have a session open. To close it, send: (1) >
ssscli disconnect
and then send
once again (2) >
ssscli connect se050 vcom <COM_NUMBER>
and later (3)
>
ssscli se05x reset
.