background image

Model 

NV-FLX-024

 

Quick Install Guide

 

Space Requirements 

1.

Select a standard 19" equipment rack or, for a standalone installation, a flat, stable surface capable of
supporting the size and weight of the FLEX24, its installable components and cabling.

2.

Ensure that you have enough rack space for all equipment. Shelves and rear supporting brackets are not
mandatory.

Location Requirements 

Power - 

The FLEX24 switch must be placed within 6 feet of an available power source. Do not use 

an extension cord to connect the equipment to a power outlet. 

Ventilation -

 

To ensure proper ventilation of the FLEX24, leave at least 2 inches of unobstructed 

space on all sides of the unit. If the fans are blocked, the unit could overheat.  

Downlink –

 The adapters should be installed a minimum of 6 feet away from the FLEX24 switch. 

Installation procedures will be trouble

free if you ensure that the following items are available 

before you begin: 

The FLEX24 switch, all cables and accessories you received in the FLEX package.

SFP transceiver modules for the Gbic uplink trunks (user-supplied) if connecting over fiber.

Fiber optic LAN cables for the Gbic uplink trunks (user-supplied) if connecting over fiber.

Standard CAT5e copper LAN cables for the GbE uplink trunks (user

supplied).

UTP cable for the downlink ports (user-supplied).

Serial console cable for the CONSOLE port, provided as an accessory in the product package.

Standard CAT5e copper LAN cable for the MGMT port (optional).  Only needed if out-of-
band management is required (user

supplied).

Protective ground cable (user

supplied).

Содержание NV-FLX-024

Страница 1: ...nect this terminal to earth ground before you make any other connections to the equipment Location and Regional Specifications The FLEX24 can be installed in any indoor location in all countries except Finland Norway and Sweden where in these 3 Nordic countries it must be installed in a restricted access location FLEX24 kan installeras på valfri plats inomhus i samtliga länder utom Finland Norge o...

Страница 2: ...ans are blocked the unit could overheat Downlink The adapters should be installed a minimum of 6 feet away from the FLEX24 switch Installation procedures will be trouble free if you ensure that the following items are available before you begin The FLEX24 switch all cables and accessories you received in the FLEX package SFP transceiver modules for the Gbic uplink trunks user supplied if connectin...

Страница 3: ...the FLEX24 5 Connect the infrastructure cable to the RJ45 on the FLEX24 switch 6 Connect the uplink cable from a Gigabit port to the NVR or network switch Note This connection also permits in band management over Ethernet when bridged mode is disabled non default setting 7 For power share daisy chain FLEX24 switches using DC cables see below 8 Power up the FLEX24 9 For troubleshooting please refer...

Страница 4: ... install the DC cables available through Phybridge as follows Note To fit properly the DC cable must be inserted into the DC input output connector with its hairpin clip on top For the top unit insert the first cable into the DC input connector on the left until it clicks into place Bring the other end of the cable down to the next unit and connect to the DC output connector on the right Continue ...

Страница 5: ...N 1 Default User Name Password User Name admin Password admin Connect to the console port 1 Connect the RJ45 end of the serial cable to the console port of the FLEX24 Connect the serial end of the serial cable to the serial port of your PC 2 Configure your serial port to 115200 8 N 1 3 Login is admin password is admin without quotes 4 You are now connected to the CLI via the console port Steps to ...

Страница 6: ...d puede tener más de una entrada de energía Para reducir el riesgo de peligro de descargas eléctricas o descargas eléctricas desconecte todas las entradas de alimentación antes de reparar la unidad To ensure adequate cooling of the equipment a 2 inch unobstructed space must be provided around all sides of the unit Um die Kühlung des Gerätes nicht zu beeinträchtigen ist es notwendig an allen Seiten...

Страница 7: ...ected to an external protective conductor Connect this terminal to earth ground before you make any other connections to the equipment The protective grounding conductor must be An Insulated wire 5 13mm2 to 14 2mm2 AWG with green and yellow stripes Connected to the grounding stud on the back of the cabinet Compliance and Environmental information All the compliance and environmental information is...

Страница 8: ... 10 100 1000 Base T autosensing independent speed selection Ethernet IEEE 802 3 CAT5e copper cable Interface Downlink PoE and IP to adapter 24 x RJ45 Jacks Speed 10 100Mb s full duplex PoE power 50 Watts Maximum per port Maximum distance Mode Cable Data Rate Reach Standard 2 pair x CAT5 10 100 Mbps 100m 328 Management 1 LAN port MGMT RJ45 10 100 Base T autosensing IEEE 802 3 1 UART console port RJ...