background image

Model 

NV-FLX-024 

Quick Install Guide

 

Beyond PoE: Delivering Power over Long Reach Ethernet

The FLEX family of data switches delivers Ethernet and Power over Ethernet over 1, 2 or 4-pair cable with multiple times 
the reach of traditional data switches.  With the FLEX24 switch customers can transform their existing cabling 
infrastructure for IP camera or IP phone deployment.

 

FLEX24 Switch 

  FLEX Package Includes: 

1.

1 x FLEX24 Unit

2.

1 x rackmount bracket kit

3.

1 x console cable

4.

1 x power cable

5.

Quick Install Guide

Installation Considerations 

The ground symbol within a circle identifies the terminal to be connected to an external 
protective conductor. Connect this terminal to earth ground before you make any other 
connections to the equipment.

 

Location and Regional Specifications 

The FLEX24 can be installed in any indoor location in all countries except Finland, Norway and Sweden, where, 
in these 3 Nordic countries, it must be installed in a restricted access location. 

FLEX24 kan installeras på valfri plats inomhus i samtliga länder utom Finland, Norge och Sverige; i dessa 
nordiska länder måste den installeras på en plats med begränsad åtkomst. 

FLEX24 kan installeres overalt indendørs undtagen i Finland, Norge og Sverige, hvor i disse tre nordiske lande 
den skal installeres på et sted med begrænset adgang. 

FLEX24 kan installeres innendørs i alle land unntatt Finland, Norge og Sverge. I disse tre nordiske landene må 
den installeres på et sted med begrenset tilgang. 

Quick Install Guide 

FLEX 24 Port Managed Switch 

Содержание NV-FLX-024

Страница 1: ...nect this terminal to earth ground before you make any other connections to the equipment Location and Regional Specifications The FLEX24 can be installed in any indoor location in all countries except Finland Norway and Sweden where in these 3 Nordic countries it must be installed in a restricted access location FLEX24 kan installeras på valfri plats inomhus i samtliga länder utom Finland Norge o...

Страница 2: ...ans are blocked the unit could overheat Downlink The adapters should be installed a minimum of 6 feet away from the FLEX24 switch Installation procedures will be trouble free if you ensure that the following items are available before you begin The FLEX24 switch all cables and accessories you received in the FLEX package SFP transceiver modules for the Gbic uplink trunks user supplied if connectin...

Страница 3: ...the FLEX24 5 Connect the infrastructure cable to the RJ45 on the FLEX24 switch 6 Connect the uplink cable from a Gigabit port to the NVR or network switch Note This connection also permits in band management over Ethernet when bridged mode is disabled non default setting 7 For power share daisy chain FLEX24 switches using DC cables see below 8 Power up the FLEX24 9 For troubleshooting please refer...

Страница 4: ... install the DC cables available through Phybridge as follows Note To fit properly the DC cable must be inserted into the DC input output connector with its hairpin clip on top For the top unit insert the first cable into the DC input connector on the left until it clicks into place Bring the other end of the cable down to the next unit and connect to the DC output connector on the right Continue ...

Страница 5: ...N 1 Default User Name Password User Name admin Password admin Connect to the console port 1 Connect the RJ45 end of the serial cable to the console port of the FLEX24 Connect the serial end of the serial cable to the serial port of your PC 2 Configure your serial port to 115200 8 N 1 3 Login is admin password is admin without quotes 4 You are now connected to the CLI via the console port Steps to ...

Страница 6: ...d puede tener más de una entrada de energía Para reducir el riesgo de peligro de descargas eléctricas o descargas eléctricas desconecte todas las entradas de alimentación antes de reparar la unidad To ensure adequate cooling of the equipment a 2 inch unobstructed space must be provided around all sides of the unit Um die Kühlung des Gerätes nicht zu beeinträchtigen ist es notwendig an allen Seiten...

Страница 7: ...ected to an external protective conductor Connect this terminal to earth ground before you make any other connections to the equipment The protective grounding conductor must be An Insulated wire 5 13mm2 to 14 2mm2 AWG with green and yellow stripes Connected to the grounding stud on the back of the cabinet Compliance and Environmental information All the compliance and environmental information is...

Страница 8: ... 10 100 1000 Base T autosensing independent speed selection Ethernet IEEE 802 3 CAT5e copper cable Interface Downlink PoE and IP to adapter 24 x RJ45 Jacks Speed 10 100Mb s full duplex PoE power 50 Watts Maximum per port Maximum distance Mode Cable Data Rate Reach Standard 2 pair x CAT5 10 100 Mbps 100m 328 Management 1 LAN port MGMT RJ45 10 100 Base T autosensing IEEE 802 3 1 UART console port RJ...

Отзывы: