background image

Model NV-EC1701U Eo2

TM

Ethernet over 2-Wire Transceiver 
with PoE+ or High Power PoE

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

7) Install in accordance with the manufacturer’s instructions.

8) Do not install near any heat sources such as radiators, heat regis-
ters, stoves or other apparatus (including DVRs) that produce heat.

9) Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other.
A grounding type plug has two blades and a third grounding prong.
The wider blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.

10) Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.

11) Only use attachments/accessories specified by the manufacturer.

12)  Refer  all  servicing  to  qualified  service  personnel.  Servicing  is
required when the apparatus has been damaged in any way, such as
a power supply cord or plug is damaged, liquid has been spilled, or
objects  have  fallen  into  the  apparatus,  the  apparatus  has  been
exposed to rain or moisture, does not operate normally, or has been
dropped. This installation should be made by a qualified service per-
son and should conform to all local codes.

13) BNC Connection: the installation shall be in accordance with the
applicable  provisions  of  the  National  Electrical  Code ANSI/NFPA  70,
Article 800.90 and Canadial Electrical Code Part 1, Section 60-504.

14) RJ45 PoE connection: to be connected only to networks or circuits
that are not routed to outside plant or building.

This installation should be made by a qualified service person and

should conform to all local codes.

WARNING - Do not install the unit in an environment where the

operating ambient temperature exceeds 185° F (85° C). The ventila-
tion should not be impeded by covering the unit with items, such as
newspapers, table-cloths, curtains, etc. No naked flame sources, such
as lighted candles should be placed on the apparatus.

WARNING - Do not interconnect multiple outputs. 

Never use

more than two power supplies within a network system.

WARNING - The apparatus shall not be exposed to dripping or

splashing and no objects filled with liquids, such as vases, shall be
placed on the apparatus.

WARNING - Use only a Certified power cord and plug (coupler /

mains) assemblies for location installed.

WARNING - Power cord is regarded as main disconnect.

WARNING  -  The  appliance  coupler  (power  cord/mains)  shall

remain readily operable.

WARNING - For safety, never put NVT signals in the same con-

duit as high-voltage wiring.

This product is intended to be supplied by a certified power source
marked “Class 2” or “LPS” and rated 48-56 VDC, minimum 840mA,
which may or may not be provided with the product.

Power supplies, when provided, are external inline, with an IEC380-
C14 power inlet and 6 ft (1.8 m) line-cord. Input Voltage is 100 ~240
VAC  50-60  Hz. A  molded  P1J  5.5  mm  barrel  connector  provides  a
Class 2 (SELV) 48-56 VDC regulated output. Line cord UL approved
type  SPT-2,  SVT,  or  SJT,  18/3 AWG  Min.  300VAC,  60°  C  Max.  15ft
(4.5m)  long.  One  end  with  IEC380-C13  appliance  coupler  and  the
other end with NEMA 1015P or equivalent for country.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT REMOVE COVER OR
BACK. NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

WARNING: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT EXPOSE THIS
APPARATUS TO RAIN OR MOISTURE.

IMPORTANT SAFETY INSTRUCTIONS

Page 1 of 12

Complete Installation Guide

Содержание NV-EC1701U Eo2

Страница 1: ...ircuits that are not routed to outside plant or building This installation should be made by a qualified service person and should conform to all local codes WARNING Do not install the unit in an environment where the operating ambient temperature exceeds 185 F 85 C The ventila tion should not be impeded by covering the unit with items such as newspapers table cloths curtains etc No naked flame so...

Страница 2: ...able in 1 4 device Eo2 TM System Kits Limited lifetime warranty The NVT Model NV EC1701U Eo2 TM Ethernet over 2 Wire Transceiver is a compact media converter that allows 10 100 BaseT Ethernet and PoE power to be transmitted using UTP STP 18 2 or similar cable These devices are often used in legacy installations where existing wire is re used as part of an upgrade to IP devices 48 or 56VDC class 2 ...

Страница 3: ...ave now entered Join Mode They will find each other and establish encrypted communication In about 10 seconds the blue Power LEDs on both transceivers will return to a steady on condition indicating a successful Join Step Four Adding Transceivers if required Disconnect transceiver 2 and replace it with a new un joined transceiver 3 or 4 or 5 Repeat steps two and three to add additional up to five ...

Страница 4: ...ductor to a terminal marked Connect the other wire conductor to a terminal marked Be sure to match the polarity of the remote end NV EC1701U If rack mounting is desired use the NV RMEC16U tray which supports up to four NV EC1701U transceivers Connect a class 2 SELV 48 or 56VDC power supply to the power jack on the NV EC1701U This will provide power to the entire system including the cam eras The B...

Страница 5: ...p that manages their security IP video can often con sume large amounts of bandwidth which may or may not be compatible with existing IT traffic Security Considerations Most surveillance systems are installed specifically to protect against breaches in security A shared LAN provides potential opportunities for unauthorized access to security assets Sniffing IP addresses can result in the unintende...

Страница 6: ...ower supplies within a network Figure 3 Alternate Power Supply Location 56V 90W Power Supply NV EC1701U NV EC1701U Model NV EC1701 www nvt com 1 650 462 8100 44 0 208 977 6614 Ethernet over Coax Transceiver Model NV EC1701 www nvt com 1 650 462 8100 44 0 208 977 6614 Ethernet over Coax Transceiver DVR NVR Ethernet Switch LAN WAN IP Camera Door Access or other IP device 60 Watt Cat5 285ft 85m Cat5 ...

Страница 7: ... Class rather than wattage If this is the case use the colored classes instead Now read over to the right until you find your kind of wire Then look up feet or down meters to find your maximum wire distance If your wire is not among the examples simply measure its total resistance and find that value on the right side of the graph The maximum supported wattage is on the left Figure 4 Power Distanc...

Страница 8: ...ower Blue Power On BNC 2 wire Interface Green Link RJ45 Interface Green Link M E C H A N I C A L E N V I R O N M E N TA L Transceiver body dimensions 5 1 in 131mm long excluding connectors 1 3 in 33mm high 1 5 in 38mm wide Transceiver weight 5 1oz 145g Operating 40 F to 185 F 40 C to 85 C storage temperature 20 to 85 RH non condensing Transient Immunity 5x20µS 3000A 6000V ESD 20KV 200pF P O W E R ...

Страница 9: ...ply 90 watts with IEC line cord NV PC4PR RJ45 Patch Cord 4 pair 3 1m Grey NV DPSC4 Detachable Power Supply Cord Splitter 1 4 2ft NV RMEC16U Rack mounting chassis 19 x 1U holds up to 4 NV EC1701U transceivers plus power supplies Includes NV DPSC4 Power Cord Splitter NV EC1701U and NV PS48 60W not included NV EC1701U Single transceiver only no power supply Product Accessories ...

Страница 10: ...tem NV EC1701U KIT2 3 NV EC1701U Transceivers 1 NV PS48 60W Power Supply with IEC line cord 3 NV PC4PR patch cord Triple Entry Station Eo2 TM Transmission System NV EC1701U KIT3 4 NV EC1701U Transceivers 1 NV PS48 60W Power Supply with IEC line cord 4 NV PC4PR patch cord Quadruple Entry Station Eo2 TM Transmission System NV EC1701U KIT4 5 NV EC1701U Transceivers 1 NV PS48 60W Power Supply with IEC...

Страница 11: ...e mented on a host such as a switch or router within the network Virtually all routers and most switches are equipped with an IGMP querier That host is responsible for sending IGMP queries to multicast devices and for generating an IGMP Report That report is moni tored by switches and routers within the network That monitoring is called IGMP Snooping These switches and routers keep a state table a...

Страница 12: ...s it pertains to those products NVT assumes no responsibility for damages or penalties incurred result ing from the use of this product in a manner or location other than for which it is intended NVT s liability under any warranties shall be discharged by replacing or repairing any part or parts which do not conform to the applicable warranty under normal and proper use NVT s liability with respec...

Отзывы: