background image

Power Supply StubEQ

TM

Receiver Hub Installation Guide

Models NV-8PS42-PVD, NV-16PS42-PVD and NV-32PS42-PVD

1) Read these instructions.
2) Keep these instructions.
3) Heed all warnings.
4) Follow all instructions.
5) Do not use this apparatus near water.
6) Clean only with a dry cloth.
7) Do not block any ventilation openings.
8) Install in accordance with the manufacturer’s instructions.
9) Do not install near any heat sources such as radiators, heat

registers, stoves or other apparatus (including DVRs) that

produce heat.
10) Do not defeat the safety purpose of the polarized or

grounding-type plug. A polarized plug has two blades with

one wider than the other. A grounding type plug has two

blades and a third grounding prong. The wider blade or the

third prong are provided for your safety. If the provided plug

does not fit into your outlet, consult an electrician for

replacement of the obsolete outlet.
11) Protect the power cord from being walked on or pinched

particularly at plugs, convenience receptacles, and the point

where they exit from the apparatus.
12) Only use attachments/accessories specified by the

manufacturer.
13) Use only with cart, stand, tripod, bracket, or table

specified by the manufacturer, or sold with the apparatus.

When a cart is used, use caution when moving the

cart/apparatus combination to avoid injury from tipover.
14) Unplug this apparatus during lightning storms or when

unused for long periods of time.
15) Refer all servicing to qualified service personnel.
Servicing is required when the apparatus has been damaged

in any way, such as a power supply cord or plug is damaged,

liquid has been spilled, or objects have fallen into the

apparatus, the apparatus has been exposed to rain or

moisture, does not operate normally, or has been dropped.

This  installation  should  be  made  by  a  qualified

service person and should conform to all local codes.

WARNING - Do not install the unit in an environment

where the operating ambient temperature exceeds 122° F 

(50°  C).  The  ventilation  should  not  be  impeded  by

covering  the  ventilation  openings  with  items,  such  as

newspapers,  table-cloths,  curtains,  etc.  No  naked  flame

sources, such as lighted candles should be placed on the

apparatus.

WARNING  -  Do  not  interconnect  multiple

outputs.

WARNING - The apparatus shall not be exposed to

dripping or splashing and no objects filled with liquids,

such as vases, shall be placed on the apparatus.

WARNING - Use only a Certified power cord and plug

(coupler / mains) assemblies for location installed.

WARNING  -  Power  cord  is  regarded  as  main

disconnect.

WARNING - Class 1 apparatus shall be connected to

a  mains  socket  outlet  with  a  protective  earthing

connection.

WARNING  -  The  appliance  coupler  (power

cord/mains) shall remain readily operable.

WARNING - For safety, never put NVT signals in the

same conduit as high-voltage wiring.

WARNING - Do not restrict airflow around any active

powered NVT products. Model NV-32PS42-PVD requires a

minimum of 2.5 in. (63.5mm) unrestricted open air space

on each side of the unit.

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT
REMOVE COVER OR BACK.  NO USER SERVICEABLE
PARTS INSIDE.  REFER SERVICING TO QUALIFIED
SERVICE PERSONNEL.

WARNING: TO REDUCE THE RISK OF ELECTRICAL
SHOCK, DO NOT EXPOSE THIS APPARATUS TO RAIN OR
MOISTURE.

IMPORTANT SAFETY INSTRUCTIONS

NV-8PS42-PVD, NV-16PS42-PVD 

or NV-32PS42-PVD

Camera Location and 

Transmitter Connections

 IDF  |  MDF  |  Control Room 

and Receiver Connections

IP

NV-216A-PV

NV-218A-PVD

Camera

The  NVT  Power  Supply  StubEQ™  Receiver  Hub  is  an  active
(amplified)  hub  that  allows  the  transmission  of  real-time
monochrome or color video for distances up to 1,500ft (460m)
using  Cat5  or  better  unshielded  twisted-pair  (UTP)  wire.    Its 
2-band  equalizer  continuously  and  automatically  compensates
for cable attenuation and ground loops, independent of the video
content.  The  1U  hub  is  equipped  with  multi-stage  transient
protection.

The  hub  combines  a  28VAC  power  supply  with  video  and
telemetry data, for 8 to 32 cameras, all over UTP wire.  Designed
for  installation  in  the  Control/MDF  room,  the  hub  consolidates
connectivity  via  standard  4-pair  RJ45  EIA/TIA  568B  compliant
premises wiring and pinouts.

At  the  camera,  power,  video,  and  data  connections  are  made
using  the  NV-216A-PV  or  NV-226J-PV  (power  &  video  only)  or
the NV-218A-PVD (power, video, and telemetry data) transceiver
via  an  RJ45  connector  and  a  single  4-pair  cable.  Control/MDF
connections are also RJ45, with BNC video outputs for the DVR,
matrix  switcher,  etc.    Telemetry  connections,  if  required,  are
supported via an RJ45 connector for each group of four camera
channels.

The  NV-8PS42  supports  up  to  8  cameras  at  up  to  1  amp  per
camera,  and  delivers  two  BNC  outputs  per  channel.    The 
NV-16PS42  supports  up  to  16  cameras  at  up  to  1  amp  per
camera,  and  delivers  two  BNC  outputs  per  channel.  The  NV-
32PS42 supports up to 32 cameras at up to 500mA per camera,
and delivers one BNC output per channel.

Wire Type

The Power Supply StubEQ

TM

Receiver operates well with Category 5 or

better Unshielded Twisted-Pair (UTP) wire, 24-22 AWG (0,5-0,64mm).

The  video  signal  may  co-exist  in  the  same  cable  tray  as  other
video, telephone, data, control signals, or low-voltage power. It is
also  OK  to  run  NVT  signals  near  electromagnetic  fields  (in
accordance  with  National  Electrical  Code,  and  other  local  safety
requirements).

DO  NOT  USE  individually  shielded  twisted  pair.  Overall  shielded,
multi-pair (6pr +) Cat5 is OK.

Do NOT use un-twisted wire.

Wire  in  underground  conduit  or  wet  locations  must  be
polyethelyne-jacketed, gel-filled.

Wire  in  plenum  environments  must  be  plenum-rated,  per  local
codes.

RS-422  and  RS-485  Pan/Tilt/Zoom  telemetry  signals  are
supported. 

Wire Distance

All measured distances include any coax in the path.

Wire resistance may be measured with an ohm-meter by shorting
the  two  conductors  together  at  the  far  end,  and  measuring  the
loop-resistance  out  and  back.  1000  feet  (300m)  of  24  AWG
(0.53mm) wire is 52 ohms; 23 AWG (0.57mm) is 42 ohms.

Wire distances are limited to the minimum of:

POWER  DISTANCE  -  the  power  loss  along  the  wire  from  the
Power Supply Passive Receiver Hub out to the camera,

- or the -

VIDEO DISTANCE - the video signal distance limit from camera to
the Power Supply StubEQ

TM

Receiver, not to exceed 1500ft (460m).

Connecting PVD at the Camera End

Use  the  NV-216A-PV  for  fixed  cameras,  or  the  NV-218A-PVD  for
fixed or P/T/Z cameras. Install per the instructions that come with
the  transmitting  device  using  4-pair  wire  and  RJ45  connectors.
NVT recommends the use of factory-crimped RJ45 patch cables
rather than unreliable field-crimped RJ45s to connect between the
NVT device and an adjacent female RJ45 jack. Wiring pinouts are:

Connecting PVD at the Power Supply
StubEQ

TM

Receiver Hub

CAUTION: Before applying power set voltage selection

switch to proper input line voltage. 

Bring the 4-pair PVD cable from each camera back to the location
of the Power Supply StubEQ

TM

Receiver. NVT recommends that an

RJ45 Patch Panel be used here in conjunction with RJ45 patch-
cords.  Use  of  these  EIA/TIA  568B  compliant  practices  allows  for
easy  testing  with  an  RJ45  (LAN)  tester,  as  well  as  moves  and
changes.

Connect the PVD signals into ports on the front of the Power Supply
StubEQ

TM

Receiver Hub.

Connect  the  IEC  cable  between  the  power  inlet  and  a  grounded
electrical outlet. Switch on the power switch and observe the blue
power LED.

Video Distance

Recommended  wire  distances  for  best  resolution  is  shown  in
chart  below.  Wire  distance  between  the  camera  and  the  Power
Supply  StubEQ

TM

Receiver  Hub  should  not  exceed  these 

recommendations:

Power Distance

Wire distance between the Power Supply StubEQ

TM

Receiver Hub

and the camera is dependent on the camera’s current draw. Please
refer to the Power Distance Charts below.

1

2

3

4

5

6

7

8

Wht/org

Org/wht 

Wht/grn

Blu/wht 

Wht/blu

Grn/wht

Wht/brn

Brn/wht

Video +

Video - 

Data +

Power - 

Power +

Data - 

Power +

Power - 

Cat 5  Wire Distance

Cat 5  Wire Distance

235

315

400

475

550

630

700

780

3 MHz

4 MHz

5 MHz

6 MHz

9 MHz

8 MHz

7 MHz

10 MHz

1

0

0

ft

C

a

m

e

ra

 L

in

e

o

f R

e

so

lu

tio

n

F

re

q

u

e

n

c

y

3

0

0

ft

1

,0

0

0

ft

1

 m

ile

3

,0

0

0

ft

1

0

,0

0

0

ft

3

0

m

1

0

0

m

3

0

0

m

1

,6

km

1

km

3

km

M

ax

P

as

s

iv

e

D

is

ta

n

c

e

M

ax

S

tu

b

E

Q

D

is

ta

n

c

e

M

a

x

D

ig

ita

lE

Q

D

is

ta

n

c

e

Fixed Camera 24VAC only, used with 

NV-216A-PV

Power Supply Voltage

Minimum Voltage at Camera

789ft (240m)

994ft (303m)

393ft (120m)

495ft (151m)

262ft (80m)

331ft (101m)

1,840ft (561m)

2,320ft (707m)

916ft (279m)

1,155ft (352m)

612ft (186m)

771ft (235m)

B&W Camera, 2.4 W

  2-pair 24 AWG

  2-pair 23 AWG

Color Camera, 4.8 W

  2-pair 24 AWG

  2-pair 23 AWG

Color Camera, 7.2 W

  2-pair 24 AWG

  2-pair 23 AWG

24 VAC

21 VAC

28 VAC

21 VAC

P/T/Z 24VAC Camera used with 

NV-218A-PVD

Power Supply Voltage

Minimum Voltage at Camera

90ft (27m)

113ft (35m)

210ft (64m)

265ft (81m)

P/T/Z Camera, 21 W

  2-pair 24 AWG

  2-pair 23 AWG

24 VAC

21 VAC

28 VAC

21 VAC

Fixed Dual Voltage 24VAC/12VDC Camera with 

NV-216A-PV

Power Supply Voltage

Minimum Voltage at Camera

1,753ft (534m)

2,210ft (674m)

874ft (266m)

1,102ft (336m)

583ft (178m)

735ft (224m)

2,454ft (748m)

3,094ft (943m)

1,223ft (373m)

1,542ft (470m)

816ft (249m)

1,029ft (314m)

B&W Camera, 2.4 W

  2-pair 24 AWG

  2-pair 23 AWG

Color Camera, 4.8 W

  2-pair 24 AWG

  2-pair 23 AWG

Color Camera, 7.2 W

  2-pair 24 AWG

  2-pair 23 AWG

24 VAC

14 VAC

28 VAC

14 VAC