background image

DigitalEQ

TM

Receiver Hub Product Installation

Manual Models NV-872, NV-1672 and NV-3272

The Digital EQ

TM

Receiver Hub is an active (ampli-

fied)  hub  that  allows  the  transmission  of  real-time
monochrome or color video for distances up to one
mile  (1,6km)  using  Category-rated  Unshielded
Twisted-Pair (UTP) wire. Note: PAL video does require
the use of Category-5 or better at 1 mile (1,6km). The
receiver hub continuously and automatically compen-
sates for cable attenuation, ground-loops, and wiring
polarity, independent of the video signal image. The
1U high hub is equipped with multi-stage transient
protection.

The NV-872 is an 8-port receiver with four DA out-

puts per channel. The NV-1672 is a 16-port receiver
with two DA outputs per channel. The NV-3272 is a
32-port receiver with one output per channel.

Wire Type

The DigitalEQ

TM

UTP Receiver Hub operates best with

category-rated Unshielded twisted-pair (UTP) wire. It
may also be used with category-rated foiled twisted-
pair (FTP) wire, or with multi-pair wire with an overall
shield (6 or more pairs). Wire gauges of 24 to 16 AWG
(0,5 to 1,3mm) are supported.

    Shielded twisted-pair (STP) wire may also be used,

up to a maximum distance of 1,000ft (300m).

    The video signal may co-exist in the same wire

bundle as other video, telephone, data, control signals,
or low-voltage power. It is also OK to run NVT signals
near  electromagnetic  fields  (in  accordance  with 
National  Electrical  Code,  and  other  local  safety 
requirements.

    Do  NOT  use  un-twisted  wire.  Due  to  near-end

crosstalk, do not send a transmit and a receive signal
in  the  same  wire  bundle.  Exception:  Up  to  1,000ft
(300m); or 2,000ft (600m) Category 5 or better.

    Up-the-Coax  Pan/Tilt/Zoom  telemetry  signals  are

NOT supported. Use a second wire-pair for RS-422 or 
RS- 485 signals instead.

    NVT recommends the use of factory-crimped RJ45

patch cables rather than unreliable field-crimped RJ45s
to  connect  between  the  NVT  deviceand  an  adjacent 
female RJ45 jack.

Wire Distance

It is recommended that the wire distance be measured
to  ensure  that  it  does  not  exceed  3,000ft  (1km),  or 
1 mile 5,280ft (1,6km) if the transmitter is an NV-653T.

Recommended Wire Distance

:

All measured distances include any coax in the path.
Wire resistance may be measured with an ohm-meter
by shorting the two conductors together at the far end,
and measuring the loop-resistance out and back.

Loop Resistance per 1,000ft (300m)

    24 AWG  (0,53 mm) 

52 ohms

    23 AWG  (0,57 mm) 

42 ohms

    22 AWG  (0,64 mm) 

33 ohms

    20 AWG  (0,81 mm) 

21 ohms

    19 AWG  (0,91 mm) 

16 ohms

    18 AWG  (1,02 mm) 

13 ohms

Wire in underground conduit or wet locations must be
polyethylene-jacketed, gel-filled. Wire in plenum envi-
ronments must be plenum-rated, per local codes.

Connecting the Camera End

  Use  any  NVT  passive  transceiver,  (such  as  the 

NV-214A-M) or qualified OEM camera with built-in UTP
output, or the NV-653T Active Transmitter. Install per the
instructions that come with the transmitting device.

1) Read these instructions.

2) Keep these instructions.

3) Heed all warnings.

4) Follow all instructions.

5) Do not use this apparatus near water.

6) Clean only with a dry cloth.

7) Do not block any ventilation openings.

8) Install in accordance with the manufacturer’s instructions.

9) Do not install near any heat sources such as radiators,
heat registers, stoves or other apparatus (including DVRs)
that produce heat.

10)  Do not defeat the safety purpose of the polarized or
grounding-type plug. A polarized plug has two blades with
one wider than the other. A grounding type plug has two
blades and a third grounding prong. The wider blade or the
third prong are provided for your safety. If the provided plug
does not fit into your outlet, consult an electrician for replace-
ment of the obsolete outlet.

11)  Protect the power cord from being walked on or pinched
particularly at plugs, convenience receptacles, and the point
where they exit from the apparatus.

12)    Only  use  attachments/accessories  specified  by  the 
manufacturer.

13)  Use only with cart, stand, tripod, bracket, or table spec-
ified by the manufacturer, or sold with the apparatus. When
a cart is used, use caution when moving the cart/apparatus
combination to avoid injury from tipover.

14) Unplug this apparatus during lightning storms or when
unused for long periods of time.

15) Refer all servicing to qualified service personnel. Servic-
ing is required when the apparatus has been damaged in any
way, such as a power supply cord or plug is damaged, liquid
has been spilled, or objects have fallen into the apparatus,
the apparatus has been exposed to rain or moisture, does
not operate normally, or has been dropped.

This installation should be made by a qualified

service person and should conform to all local codes.

WARNING - Do not install the unit in an environ-

ment where the operating ambient temperature exceeds

1220° F (50° C). The ventilation should not be impeded

by covering the ventilation openings with items, such as

newspapers, table-cloths, curtains, etc. No naked flame

sources, such as lighted candles should be placed on

the apparatus.

IMPORTANT SAFETY INSTRUCTIONS

TO REDUCE THE RISK OF ELECTRICAL SHOCK,

DO NOT REMOVE COVER OR BACK.  NO USER

SERVICEABLE PARTS INSIDE.  REFER SERVICING

TO QUALIFIED SERVICE PERSONNEL.

WARNING: TO REDUCE THE RISK OF ELECTRI-
CAL SHOCK, DO NOT EXPOSE THIS APPARATUS
TO RAIN OR MOISTURE.

WARNING - Do not interconnect multiple 

                 outputs.

  WARNING - The apparatus shall not be exposed 

           to dripping or splashing and no objects filled with 

           liquids, such as vases, shall be placed on the 

           apparatus.

  WARNING - Use only a Certified power cord and 

           plug (coupler / mains) assemblies for location 

           installed.

  WARNING - Power cord is regarded as main 

           disconnect.

  WARNING - The appliance coupler (power 

           cord/mains) shall remain readily operable.

  WARNING - For safety, never put NVT signals in 

           the same conduit as high-voltage wiring.

  WARNING - Do not restrict airflow around any 

           active powered NVT products.

Cat 5  Wire Distance

Cat 5  Wire Distance

235

315

400

475

550

630

700

780

3 MHz

4 MHz

5 MHz

6 MHz

9 MHz

8 MHz

7 MHz

10 MHz

1

0

0

ft

C

a

m

e

ra

 L

in

e

o

f R

e

so

lu

tio

n

F

re

q

u

e

n

c

y

3

0

0

ft

1

,0

0

0

ft

1

 m

ile

3

,0

0

0

ft

1

0

,0

0

0

ft

3

0

m

1

0

0

m

3

0

0

m

1

,6

km

1

km

3

km

M

ax

P

as

s

iv

e

D

is

ta

n

c

e

M

ax

S

tu

b

E

Q

D

is

ta

n

c

e

M

a

x

D

ig

ita

lE

Q

D

is

ta

n

c

e

Отзывы: