72
Set access register data (PAOS in unknown mode (RAW) with indexes: local_port=0x1 swid=0x0 and
data e 1):
mstreg -d
41
:
00.0
--reg_id
0x5006
--reg_len
0x10
--indexes
"0x0.16:8=0x1,0x0.24:8=0x0"
--yes --set
"0x4.0:2=0x1"
You are about to send access register id:
0x5006
with the following data:
Address | Data
=======================
0x00000000
|
0x00010101
0x00000004
|
0x00000001
0x00000008
|
0x00000000
0x0000000c
|
0x00000000
=======================
Do you want to
continue
? (y/n) [n] : y
Sending access register...
mstlink Utility
The mstlink tool is used to check and debug link status and issues related to them. The tool can be
used on different links and cables (passive, active, transceiver, and backplane).
mstlink Usage
To run mstlink:
mstlink [OPTIONS]
where:
Options:
-h |--help
Display help message.
-v |--version
Display version info.
-d |--device <device>
Perform operation for a specified mst device
-p |--port <port_number>
Port Number
--port_type <port_type>
Port Type [NETWORK(Default)/PCIE/OOB]
--depth <depth>
Depth level of the DUT of some hierarchy (valid for PCIe
port type only)
--pcie_index <pcie_index>
PCIe index number (Internal domain index) (valid for PCIe
port type only)
--node <node>
The node within each depth (valid for PCIe port type only)
--json
Print the output in json format
Queries:
•
•
•
mstlink is intended for advanced users with appropriate technical background.
When using mstlink to disable the port state ("--port_state dn" flag) on a NIC
connected through a Socket-Direct connection, the port must be disabled on both
mst devices representing the physical port.
When running mstlink to show SLTP for 16nm technology, the “--advanced” flag
should be added to the run command.