CPCI System Subrack 2 U

User’s Manual

Product No.:

24579-081

April 14, 2011

Doc-No: 63972-233_R1.1 

Содержание Schroff 24579-081

Страница 1: ...CPCI System Subrack 2 U User s Manual Product No 24579 081 April 14 2011 Doc No 63972 233_R1 1...

Страница 2: ...001 2000 The company cannot accept any liability for errors or misprints The company reserves the right to amendments of technical specifications due to further development and improvement of products...

Страница 3: ...em Overview 3 2 3 Subrack 4 2 4 CPCI Backplane 4 2 5 Power Supply 5 2 5 1 Grounding Earthing 5 2 5 2 ATX Power Supply 6 2 6 Cooling 7 2 7 Remove Install Fan Tray 7 3 Installation 9 3 1 General Install...

Страница 4: ...CPCI System Subrack 2 U 24579 081 www schroff biz II R1 1 April 18 2011...

Страница 5: ...is no valid approval for this unit In order to enable stand alone functionality additional elements are required An operational system is achieved only by way of appropiate CPCI boards The completion...

Страница 6: ...s to avoid accidents before starting to work with parts that carry dangerous voltages Caution This is the user caution symbol It indicates a condition where damage of the equipment or injury of the se...

Страница 7: ...50 W with wide range input Fans for the active cooling of the boards DC switch 2 1 References and Architecture Specifications User Manual CPCI Backplanes Order no 73972 101 Technical Data Schroff CPCI...

Страница 8: ...4 Rear I O Boards 6 U 4 HP 80 mm deep The right guide rails of the card cage are equipped with ESD clips 2 4 CPCI Backplane The horizontally assembled 6 U Backplane provides CompactPCI bus PICMG2 0 R...

Страница 9: ...s of the power supply may be exposed with hazardous voltage Always remove mains line connector before carry out any assembly work Caution Your system has not been provided with a AC power cable Purcha...

Страница 10: ...down Short circuit protection 3 3 V 5 V 12 V shut down 5 V 12 V 5 VSB auto recovery Over voltage protection 3 3 V 3 6 4 2 V 5 V 5 6 6 6 V 12 V 13 2 14 6 V Ripple 3 3 V 60 mV 5 V 50 mV 12 V 120 mV 12 V...

Страница 11: ...s by a mini compression latch with indicator red green In closed position the indicator shows green in open position the indicator shows red Remove Fan Tray Turn the knob counterclockwise until the in...

Страница 12: ...tion 24579 081 www schroff biz 8 R1 1 April 18 2011 Figure 4 Airflow 12308828 Caution To maintain proper airflow all open slots must be covered with filler panels The filler panel should include an ai...

Страница 13: ...en rack whenever possible If installation in an enclosed rack is unavoidable ensure that the rack has adequate ventilation Maintain ambient airflow to ensure normal operation If the airflow is blocked...

Страница 14: ...oid uneven mechanical loading of the rack 3 3 Initial Operation Ensure that the system has not been damaged during transport storage or assembly Check the Protective Earth PE resistance should be 0 1...

Страница 15: ...C regulations and therefore a CE marking is not required However when CPCI cards are assembled according to specification the systems fulfill the requirements in accordance with EMC Directive 2004 108...

Страница 16: ...ight 1 Rear card cage for max 4 boards 6 U 80 mm deep IEEE guide rails inc ESD clips 1 250 W ATX power supply with input range of 100 VAC to 240 VAC with 4 voltages 3 3 V 14 A 5 V 23 A 12 V 16 A 12 V...

Страница 17: ...250 W Cooling 2 x 12 VDC fans 109 m h 64 cfm each free blow Ambient Temperature Operation 0 C to 50 C Storage 40 C to 85 C Humidity Admissible humidity 30 to 80 non condensing EMC fulfils requirements...

Страница 18: ...CPCI System Subrack 2 U Dimensions 24579 081 www schroff biz 14 R1 1 April 18 2011 6 Dimensions Figure 5 Dimensions...

Страница 19: ......

Страница 20: ...SCHROFF GMBH www schroff biz Langenalberstr 96 100 Tel 49 0 7082 794 0 Fax 49 0 7082 794 200 D 75334 Straubenhardt...