background image

DESCRIPTION

nVent RAYCHEM RayClic-S Splice Kit
nVent RAYCHEM RayClic-T Tee and End Seal Kit
nVent RAYCHEM RayClic-X Cross and End Seal Kit

These kits are for use with nVent RAYCHEM IceStop, XL-Trace 

and HWAT heating cables. The connection is designed to 

be strapped to the pipe, or wall mounted. These installation 

instructions should be used in conjunction with the IceStop, 

XL-Trace, and HWAT System Installation and Operation Manuals. 

For  technical support, contact your nVent representative or call 

nVent (800) 545-6258.

TOOLS REQUIRED

•  TORX T20 screw driver

•  Utility knife

•  Wire cutters

OPTIONAL ACCESSORIES  

(NOT INCLUDED IN THIS KIT)

•  RayClic-SB-02 Wall mounting bracket
•  RayClic-SB-04 Pipe mounting bracket

This component is an electrical device that 

must be installed correctly to ensure proper 

operation and to prevent shock or fire. Read 

these important warnings and carefully follow 

all the installation instructions.
•  To minimize the danger of fire from 

sustained electrical arcing if the heating 

cable is damaged or improperly installed, 

and to comply with the requirements of 

nVent, agency certifications, and national 

electrical codes, ground-fault equipment 

protection must be used. Arcing may not be 

stopped by conventional circuit breakers.

•  Bus wires will short if they contact each 

other. Keep bus wires separated.

•  Keep components and heating cable ends 

dry before and during installation.

•  The black heating cable core is conductive 

and can short. It must be properly insulated 

and kept dry.

•  Component approvals and performance are 

based on the use of nVent-specified parts 

only. Do not use substitute parts or vinyl 

electrical tape.

•  Leave these instructions with end user for 

reference and future use.

WARNING:

APPROVALS

For HWAT, IceStop, and XL-Trace only

Hazardous Locations: For IceStop (GM-XT) only

Class I, Div. 2, Groups A,B,C,D

718K Pipe Heating Cable

877Z De-Icing and Snow Melting

Not UL Listed with XL-Trace heating cable 

for buried piping.

APPROVED

-w

RayClic Connection System

Installation Instructions

Содержание Raychem RayClic Series

Страница 1: ...instructions To minimize the danger of fire from sustained electrical arcing if the heating cable is damaged or improperly installed and to comply with the requirements of nVent agency certifications...

Страница 2: ...1 splice 2 warning E 1 Cable lubricant RAYCLIC T TEE KIT Item Qty Description A 1 Tee B 2 Plastic cable ties C 3 Clips D 1 End seal E 3 Labels 1 splice 2 warning F 1 Cable lubricant RAYCLIC X CROSS K...

Страница 3: ...pipe and attach with plastic cable ties Score around and down the outer jacket of the heating cable 3 1 8 inches from the end Allow enough extra heating cable to make service loops as required Make su...

Страница 4: ...cut away 1 inch of the braid Pull exposed braid back over metal clip Using wire cutters cut away aluminum wrap Pull exposed braid back over metal clip IceStop and XL Trace Only HWAT Only nVent RAYCHEM...

Страница 5: ...e compressed Repeat steps 2 through 7 for all remaining heating cable entries Using glass cloth tape attach heating cable to pipe Apply insulation cladding warning labels and yellow splice identificat...

Страница 6: ...steps 2 through 9 pages 3 5 Attach connector to mounting bracket by pressing until it snaps into place Complete heating cable installation and install drip loops as shown Protect heating cable from sh...

Страница 7: ...Remove the outer jacket Do not cut or damage inner jacket Using wire cutters cut away aluminum wrap close to braid and outer jacket Remove exposed braid Push end seal completely onto heating cable No...

Страница 8: ...ating cable does not have aluminum wrap Only HWAT heating cables have the aluminum wrap under the braid Skip the aluminum wrap removal step for XL Trace and IceStop heating cables Heating cable cannot...

Страница 9: ...detail heating cable operation refer to the appropriate installation and operating manual Instructions 1 Open the RayClic Cover 2 Set multimeter to AC voltage function 3 Insert multimeter test probes...

Страница 10: ...cations without notice Raychem IM H55388 RayClicConnectionKits EN 1805 PN 473303 000 nVent com North America Tel 1 800 545 6258 Fax 1 800 527 5703 thermal info nvent com Europe Middle East Africa Tel...

Отзывы: