18 | nVent.com
9 TECHNICAL SPECIFICATION
Supply voltage
/- 10%, 50Hz
Power consumption in
Sleep mode
400 mW
Power consumption in
Max. load
1000 mW
Main power switch
2-pole
Relay output
230V, max. 13A
Setpoint range
0°C to 40°C
Ambient temperature
– transport
-20°C to +70°C
Protection class
IP21
Terminals
2,5 mm
2
Screw cage clamp
Floor sensor with 3 m
cable
12k @ 25°C +/- 0.75°C
(no:38165)
Maximum length of
floor sensor cable
100m, 2 x 1,5mm²
(230VAC cable)
Dimension with frame
84 X 84 X 40mm
Color rounded front
RAL 9010
Color square front
RAL 9003
Color switch gear frame RAL 9010
Display
1.8’’ Dot Matrix LCD display
(100 x 64 pixels) with blue
backlight
Control modes
Floor Sensor (active when floor
sensor installed and connected)
Room Sensor with floor limiter
(active when floor sensor
installed and connected)
Room Sensor (active when no
floor sensor is connected)
No Sensor % regulator with
cycles of 20 minutes (active
when no floor sensor is
connected)
Working modes
Constant Mode, Event Mode,
Boost Mode