MEC 5000, 6500 & 8000/P |
21
www.natvac.com | 800.253.5500
Troubleshooting
MEC 5000/P
MEC 6500/P
MEC 8000/P
Pump overheats
• No oil in pump
• Oil adjustment set too lean
• Rpm too fast
• Prolonged operation
Too much oil use
• Oil adjustment set too rich
• Oil seals defective
• Cracked pump body
Pump doesn’t turn
•
Broken vane
•
Frozen
•
Pump endplate bolts too tight
•
Faulty PTO or drive set up
No vacuum or pressure in tank
•
Suction valve in neutral
•
Defective seal or vanes
•
Pump not driven fast enough
•
Check valve or suction line clogged
•
Leak in tank or fittings