NuWaves NW-BA-VU-4-GX02 Скачать руководство пользователя страница 9

NuPower Xtender™ VU4GX02 User Manual 

 

 

Rev 1.2 

 

4.4

 

OVER TEMPERATURE FLAG 

This signal is an output to indicate an over‐temperature condition in the NuPower Xtender VU4GX02.  A 
logic high (+5 VDC) indicates normal operation, while a logic low (0 VDC) indicates an over‐temperature 
condition.  The Xtender VU4GX02 incorporates internal logic circuitry that turns off the DC bias to the RF 
transistors.  

 

Caution:  The  amplifier  should  be  shut  down  and  allowed  to  cool  off  when  the  over‐
temperature flag is set low to avoid damage to the module. 
 
 

4.5

 

TRANSMIT/RECEIVE (T/R) ENABLE 

The Xtender transmit and receive switching is a manual control  function.  Applying a logic 

low

 (0 V or 

GND) to the T/R line places the VU4GX02 in transmit mode.  Likewise applying either a logic 

high

 (+5 V) 

to the T/R line, or leaving it float (NC), places the VU4GX02 in receive mode.  
 

 

Содержание NW-BA-VU-4-GX02

Страница 1: ...OWER XTENDER VU4GX02 BIDIRECTIONAL VHF UHF AMPLIFIER PART NUMBER NW BA VU 4 GX02 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sal...

Страница 2: ...orated into the chassis Completely Characterized The NuPower Xtender family of solid state bidirectional amplifiers has been completely characterized over temperature voltage and frequency These high...

Страница 3: ...16 watts Psat or 4 watts of linear RF transmit power 30 dBc ACPR from 225 to 512 MHz in transmit mode and the integrated low noise amplifier provides 15 dB of gain in receive mode Based on the latest...

Страница 4: ...nsmit RF Gain 36 dB typ Nominal Input Drive Level 5 dBm Maximum Input Drive Level 30 dBm Receive RF Gain 15 dB min Receive Noise Figure 2 5 dB typ T R Mode Manual T R Line T R Switch Time 8 S Supply V...

Страница 5: ...IONS Figure 2 NuPower Xtender VU4GX02 Mechanical Outline Table 3 NuPower Xtender VU4GX02 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 15...

Страница 6: ...mperatures may require additional heat sinking to maintain a baseplate temperature below 60 C at 100 transmit duty cycle Figure 3 The NuPower PA Kit offers out of the box operation for the user The fa...

Страница 7: ...tly connecting to an antenna specified for the frequency range 225 to 512 MHz Connecting to an inappropriate antenna may result in damage to the amplifier module Connecting to a proper antenna through...

Страница 8: ...NTERFACE CONNECTOR The NuPower Xtender VU4GX02 features a 15 pin Micro D interface connector for control power and ground connections Table 4 NuPower Xtender Interface Pin Out Definitions Socket No Na...

Страница 9: ...nternal logic circuitry that turns off the DC bias to the RF transistors Caution The amplifier should be shut down and allowed to cool off when the over temperature flag is set low to avoid damage to...

Страница 10: ...sposing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted munic...

Страница 11: ...d Sales Email product sales nuwaves com Phone 513 360 0800 NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERA...

Отзывы: