background image

NuPower

TM

 

L60T01

 

User

 

Manual

    

 

 

 

Rev

 

1.1

 

7

 

 

3

 

SETUP AND OPERATION 

This

 

section

 

provides

 

specific

 

details

 

for

 

proper

 

operation

 

of

 

the

 

NuPower

 

L60T01

 

module.

 

Following

 

these

 

guidelines

 

will

 

prevent

 

damage

 

to

 

the

 

power

 

amplifier

 

or

 

external

 

equipment.

 

3.1

 

POWER SUPPLY REQUIREMENTS 

To

 

operate

 

the

 

NuPower

 

L60T01,

 

ensure

 

that

 

the

 

power

 

supply

 

has

 

adequate

 

overhead

 

to

 

source

 

the

 

current

 

demand

 

of

 

the

 

RF

 

power

 

amplifier.

 

The

 

power

 

supply

 

source

 

must

 

provide

 

a

 

typical

 

voltage

 

of

 

+28

 

VDC

 

with

 

greater

 

than

 

5

 

amps

 

capability.

  

3.2

 

CONNECTING A PROPER LOAD TO THE ANTENNA TERMINAL 

To

 

prevent

 

damage

 

to

 

the

 

PA,

 

the

 

antenna

 

terminal

 

must

 

be

 

terminated

 

into

 

a

 

50

 

Ω

 

load.

 

Examples

 

of

 

a

 

proper

 

load

 

include:

 

 

 

Directly

 

connecting

 

to

 

an

 

antenna

 

specified

 

for

 

the

 

frequency

 

range

 

(960

 

MHz

 

to

 

1390

 

MHz).

 

Connecting

 

to

 

an

 

inappropriate

 

antenna

 

may

 

result

 

in

 

damage

 

to

 

the

 

PA

 

module.

  

 

Connecting

 

to

 

a

 

proper

 

antenna

 

through

 

a

 

50

 

Ω

 

transmission

 

line

 

or

 

coaxial

 

cable.

 

Avoid

 

using

 

damaged

 

cables

 

or

 

corroded

 

connectors

 

while

 

attaching

 

the

 

unit

 

to

 

an

 

antenna.

 

 

Terminating

 

the

 

antenna

 

terminal

 

into

 

a

 

50

 

Ω

 

power

 

attenuator

 

with

 

minimum

 

20

 

dB

 

attenuation.

 

 

Connecting

 

to

 

a

 

load

 

capable

 

of

 

dissipating

 

the

 

RF

 

power

 

from

 

the

 

PA

 

module.

 

Loads

 

capable

 

of

 

handling

 

50

 

Watts

 

(min)

 

are

 

recommended.

  

3.3

 

POWERING

UP THE NUPOWER L60T01 

The

 

NuPower

 

L60T01

 

must

 

be

 

terminated

 

to

 

a

 

proper

 

load

 

before

 

power

 

is

 

applied.

 

Refer

 

to

 

Section

 

3.2

 

for

 

the

 

specifications

 

of

 

the

 

proper

 

load.

 

After

 

the

 

PA

 

is

 

properly

 

terminated,

 

the

 

interface

 

cable

 

can

 

be

 

connected

 

to

 

the

 

unit

 

and

 

power

 

can

 

be

 

applied.

 

The

 

PA

 

is

 

now

 

ready

 

for

 

operation.

  

3.4

 

TRANSMIT TURN

ON TIME 

 

Caution:

 

Do

 

not

 

apply

 

transmit

 

data

 

until

 

the

 

PA

 

module

 

is

 

at

 

full

 

power.

 

This

 

will

 

prevent

 

loss

 

of

 

data

 

at

 

the

 

beginning

 

of

 

a

 

message.

 

 

The

 

NuPower

 

L60T01

 

is

 

at

 

full

 

power

 

approximately

 

1

 

µS

 

after

 

the

 

RF

 

Enable

 

line

 

goes

 

low

 

(ground).

 

Therefore,

 

transmit

 

data

 

can

 

be

 

applied

 

to

 

the

 

input

 

after

 

1

 

µS

 

without

 

loss

 

of

 

data.

 

3.5

 

RF OUTPUT POWER VS. SUPPLY VOLTAGE 

The

 

NuPower

 

L60T01

 

was

 

designed

 

for

 

+28

 

VDC

 

operation.

 

 

Содержание NUPOWER L60T01

Страница 1: ...MANUAL NUPOWERTM L60T01 L BAND POWER AMPLIFIER PART NUMBER NW PA L60T01 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sales nuwave...

Страница 2: ...letely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer significant value...

Страница 3: ...l for size weight and power constrained RF telemetry and tactical communication systems The NuPowerTM L60T01 ruggedized chassis allows the system integrator to easily incorporate the unit into a platf...

Страница 4: ...t Power 1 dB Compression 41 dBm 960 MHz 43 dBm 1175 MHz 43 dBm 1390 MHz RF Gain 48 dB typ Input VSWR 1 9 typ 2 3 max Output Mismatch No Damage 10 1 Nominal Input Drive Level 0 dBm Maximum Input Drive...

Страница 5: ...Temperature 40 to 60 o C ambient 40 to 85 o C baseplate Storage Temperature 55 to 85 o C Table 3 NuPower L60T01 Mean Time Between Failure MTBF Conditions Hours Ground Benign GB 292 657 Airborne Inhab...

Страница 6: ...NICAL SPECIFICATIONS Figure 2 NuPower L60T01 Mechanical Outline Table 4 NuPower L60T01 Mechanical Specifications Parameter Specification RF Connectors SMA female Control Power Interface Connector 9 Pi...

Страница 7: ...banana plugs Figure 3 The NuPower PA Kit offers out of the box operation for the user The 28 VDC fan cooled heatsink is shown with the NuPower L60T01 mounted Caution The use of external heat sinking i...

Страница 8: ...nsmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB...

Страница 9: ...ed into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of the NuPower L60T01 is made up of 9 wires...

Страница 10: ...in transmit mode The user can either connect the RF Enable line to pins 1 2 6 8 on the CTRL PWR interface connector or an open drain logic line capable of sinking 500 A to place the unit in transmit m...

Страница 11: ...sing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipa...

Страница 12: ...Sales Phone 513 360 0800 Email support nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL INFOR...

Отзывы: