background image

NuPower

TM

 C30R01 User Manual    

 

 

 

Rev 1.0 

 

2.3

 

HEAT SINKING 

The NuPower C30R01  is offered as a stand-alone module or with an accessory kit 

 

(P/N: NW-PA-ACC-KT03), which includes a 28 VDC fan-cooled heatsink and requisite power cable. [The kit 

also includes an upgraded module interface cable assembly, labeled and terminated with banana plugs.] 
 

 

Figure 3: The NuPower PA Kit offers “out-of-the-box” operation for the user. The 28 VDC fan-cooled 

heatsink is shown with the NuPower C30R01 mounted.  

 
 

 

 

Caution:  The use of external  heat-sinking is required especially  for  those  applications 

requiring high  duty cycle operation  (e.g. continuous wave)  or for extended on-time 

testing.  Operation without a proper heat sink under these conditions will cause 

permanent damage to the product and will void the product warranty. 

 

The max operating temperature is 85˚ C 

(baseplate). 

 

 

 

 
 

 

Содержание NUPOWER C30R01

Страница 1: ...ANUAL NUPOWERTM C30R01 C BAND POWER AMPLIFIER PART NUMBER NW PA C 30 R01 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves com product sales nuwav...

Страница 2: ...he chassis Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature voltage and frequency These high performance modules offer sig...

Страница 3: ...N technology NuPower L Band power efficiency and 10 in3 cubic inch form factor make it ideal for size weight and power constrained broadband RF telemetry and tactical communication systems The NuPower...

Страница 4: ...n Output Power 1 dB Compression 28 dBm 5030 MHz 29 dBm 5060 MHz 29 dBm 5090 MHz RF Gain 45 dB Input VSWR 2 3 typ Output Mismatch No Damage 10 1 Nominal Input Drive Level 0 dBm Maximum Input Drive Leve...

Страница 5: ...C ambient 40 to 85 o C baseplate Storage Temperature 55 to 85 o C 2 2 NUPOWER C30R01 PA MECHANICAL SPECIFICATIONS Figure 2 NuPower C30R01 Mechanical Outline Table 3 NuPower C30R01 Mechanical Specifica...

Страница 6: ...banana plugs Figure 3 The NuPower PA Kit offers out of the box operation for the user The 28 VDC fan cooled heatsink is shown with the NuPower C30R01 mounted Caution The use of external heat sinking i...

Страница 7: ...nsmission line or coaxial cable Avoid using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB...

Страница 8: ...NuPowerTM C30R01 User Manual Rev 1 0 7...

Страница 9: ...ion This connection should always be loaded into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 9 pin Micro D connector of...

Страница 10: ...Grounding the pin i e a voltage below 0 2 VDC places the unit in transmit mode The user can either connect the RF Enable line to pins 1 2 6 8 on the CTRL PWR interface connector or an open drain logic...

Страница 11: ...sing of a NuWaves product Do not remove the cover or any hardware Do not remove components from the circuit card assembly Do not incinerate Do not crush or shred Do not dispose of as unsorted municipa...

Страница 12: ...g and Sales Phone 513 360 0800 Email support nuwaves com NuWaves Home Page https www nuwaves com Product Warranty https nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL INFORMATI...