background image

NuPower

TM

 11B02A-TAC2 User Manual    

 

 

 

Rev 1.0 

 

3

 

SETUP AND OPERATION

 

This  section  provides  specific  details  for  proper  operation  of  the  NuPower  11B02A-TAC2  module. 
Following these guidelines will prevent damage to the power amplifier or external equipment. 

3.1

 

POWER SUPPLY REQUIREMENTS 

To operate the NuPower 11B02A-TAC2, ensure that the power supply has adequate overhead to source 
the current demand of the RF power amplifier. The power supply source must provide a typical voltage of 
+28 VDC with greater than 3 amps capability (or equivalent current based on acceptable 11-32V input 
voltage range).  

3.2

 

CONNECTING A PROPER LOAD TO THE ANTENNA TERMINAL 

To prevent damage to the PA, the antenna terminal must be terminated into a 50 

Ω

 load. Examples of a 

proper load include: 
 

 

Directly  connecting  to  an  antenna  specified  for  the  frequency  range  (200  MHz  to  2.6  GHz). 
Connecting to an inappropriate antenna may result in damage to the PA module.  

 

Connecting to a proper antenna through a 50 

Ω

 transmission line or coaxial cable. Avoid using 

damaged cables or corroded connectors while attaching the unit to an antenna. 

 

Terminating the antenna terminal into a 50 

Ω

 power attenuator with minimum 20 dB attenuation. 

 

Connecting to a load capable of dissipating the RF power from the PA module. Loads capable of 
handling 30 Watts (min) are recommended.  

3.3

 

POWERING-UP THE 11B02A-TAC2 

The NuPower 11B02A-TAC2 must be terminated to a proper load before power is applied. Refer to Section 
3.2 for the specifications of the proper load. After the PA is properly terminated, the interface cable can 
be connected to the unit and power can be applied. The PA is now ready for operation.  

3.4

 

TRANSMIT TURN-ON TIME 

 

Caution: Do not apply transmit data until the PA module is at full power. This will prevent 
loss of data at the beginning of a message. 

 

The NuPower 11B02A-TAC2 is at full power approximately 30 µS after the RF Enable switch is placed in 

the ‘ON’ position

. Therefore, transmit data can be applied to the input after 30 µS without loss of data. 

3.5

 

RF OUTPUT POWER VS. SUPPLY VOLTAGE 

Although  the  NuPower  11B02A-TAC2  was  designed  for  +28  VDC  operation,  the  module  is  capable  of 
providing suitable RF power output over a broad range of supply voltages: +11 VDC to +32 VDC. 
 

Содержание NuPower 11B02A-TAC2

Страница 1: ...1B02A TAC2 MINI MULTI OCTAVE POWER AMPLIFIER W INTEGRATED HEATSINK PART NUMBER NW PA 11B02A TAC2 NuWaves Engineering 132 Edison Drive Middletown Ohio 45044 PH 513 360 0800 FAX 513 539 8782 www nuwaves...

Страница 2: ...d aluminum enclosure with mounting holes incorporated into the chassis Completely Characterized The NuPower family of solid state power amplifiers has been completely characterized over temperature vo...

Страница 3: ...ation systems The NuPower 11B02A TAC2 s rugged IP67 rated chassis with integrated heat sink allows the system integrator or operator to easily incorporate the unit into a platform operating in harsh e...

Страница 4: ...2 NuPower 11B02A TAC2 Environmental Specifications Operating Conditions Specification Operating Temperature Ambient 40 to 60 o C Operating Temperature Baseplate 40 to 85 o C Storage Temperature 55 to...

Страница 5: ...ATIONS Figure 2 NuPower 11B02A TAC2 Mechanical Outline Table 4 NuPower 11B02A TAC2 Mechanical Specifications Parameter Specification RF Connectors Input Output TNC Female N Female Control Power Interf...

Страница 6: ...go low 0VDC and bias to internal amplifiers will be removed until cooled to approximately 70 C Note If desired factory can reduce thermal shutdown point to protect users if worn on body Contact sales...

Страница 7: ...id using damaged cables or corroded connectors while attaching the unit to an antenna Terminating the antenna terminal into a 50 power attenuator with minimum 20 dB attenuation Connecting to a load ca...

Страница 8: ...2A TAC2 will be in standby mode Pulling the line low 0 5VDC to 1 5VDC or GND will place the module in transmit mode Note The RF Enable line is pulled high internally and does not require applying a vo...

Страница 9: ...into 50 otherwise the PA could be damaged 4 1 INTERFACE CABLE HARNESS The cable harness that connects the host controller to the 4 pin bayonet connector of the NuPower 11B02A TAC2 is made up of 4 wir...

Страница 10: ...isposal Improper disposal can adversely affect the environment wildlife and human health Please follow these guidelines when disposing of a NuWaves product Do not remove the cover or any hardware Do n...

Страница 11: ...ing and Sales Phone 513 360 0800 Email sales nuwaves com NuWaves Home Page http www nuwaves com Product Warranty https products nuwaves com wp content uploads NuWaves_Warranty_Repair pdf 6 1 GENERAL I...

Отзывы: