NU-LINK-GANG PROGRAMMER SETUP
3.1
Choose the Programming Voltage
The Nu-Link-Gang supports three kinds of programming voltage, 1.8 V, 3.3 V, or 5.0 V. Users can
choose different programming voltage for each programming unit by setting corresponding
programming voltage switch. Please sets the programming voltage before the Nu-Link-Gang power
on.
3.2
Set the Programming Mode
Switch the programming mode to single-start or all-start.
3.3
Load Firmware Image Files through NuMicro
®
ICP Programming Tool
Please access Nuvoton NuMicro
®
website (http://www.nuvoton.com/NuMicro) to download the
NuMicro ICP tool - ICP Programming Tool
. Unzip the file and execute “NuMicro ICP Programming
Tool.exe”. Please refer to section 3.3.1 and 3.3.2 for the detailed flow. For more information, please
refer to the “Nuvoton NuMicro ICP Programmer User Guide”.
3.3.1 Connect to ICP Programming Tool
Connects one programming unit’s to PC through USB connector as Figure 3-1, then open the ICP
Programing Tool on the PC.
Figure 3-1 Nu-Link-Gang Connects to PC
3.3.2 ICP Programming Tool Setting
1.
Choose “Connect”. The window will shows “NuLink connected” when the connection between
programming unit and ICP Programming Tool is built.