background image

7

I.  Installing the T2DAB in the Home

Connecting the Audio Outputs (Fig. 1)

The T2DAB has two independent audio outputs labeled A and B. 
These are standard stereo RCA connections and can be 
connected to any device designed to receive an analog stereo 
audio signal.

Setting the Audio Outputs for NuVoNet or Standalone use 
(Fig. 2)

The outputs A and B are individually set from the front panel 
display of the T2DAB. When the tuner is initially plugged into 
an AC power source, a short setup wizard will appear on the 
display. A message, “Uninitialized State Detected (Press OK)” 
will appear. When OK is pressed, the prompt is to select a 
regional tuning standard. The choices are USA/Canada, 
Western Europe, Australia, and New Zealand. Use the Up and 
Down arrows to highlight the appropriate choice and touch the 
OK button to select. Once regional tuning has been selected, 
the display will prompt for the use of each output A and B. 
“+Output A” will highlight automatically. Using the up and 
down arrows on the front panel, move the highlight to the 
appropriate use of the tuner output and touch OK. The choices 
are 

Stand Alone, Source 1, Source 2, Source 3, Source 4, Source 

5, and Source 6.  

For any use other than with the Essentia E6G 

or Grand Concerto Systems, select Stand-alone. This will 
require IR or serial control of the T2DAB's functions. 
Highlighting the appropriate Source number input for the NuVo 
system and touching the OK button sets NuVoNet 
communication. Once Output A is set, the highlight will move 
to Output B. For operation, both outputs A and B must be set as 
Stand Alone or as a NuVoNet Source. 

When the Tuner's outputs are set, they will return to FM 87.9, 
or the minimum FM band setting for the selected regional 
tuning parameters. At this point the T2DAB is ready for either 
NuVoNet communication or standalone use, depending on the 
setting made for both outputs.

DAB  Channel Scan (Fig. 3)

The DAB tuner will run a full channel scan of the entire DAB 
frequency range after the initial setup simultaneously for both 
tuners A and B. The ensemble count and available stations will 
increment as the scan completes itself. After the scan is 
complete, the number of (on-air) channels found is displayed.

ANTENNA

IN

USE NV-T2FAA 

ANTENNA

L

AUDIO

R

TUNER A

L

AUDIO

R

TUNER B

SOURCE LINK

L

R

L

R

L

R

SOURCE INPUTS 

TIP=L

RING=R

ZONE 2

VARIABLE

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

VARIABLE

OUTPUT

FIXED

OUTPUT

   TIP=L
RING=R

1

2

3

4

5

6

1

2

3

4

5

6

1

2

3

4

CONNECT TO

NV-I8X

USE NV-SLC1

CABLE

5

6

ZONE 1

VARIABLE

OUTPUT

FIXED

OUTPUT

 SPEAKER

 40W/6 OHMS X 2

LEFT        RIGHT

ZONE 3

ZONE 4

SOURCE STATUS

 SPEAKER

 40W/6 OHMS X 2

LEFT        RIGHT

 SPEAKER

 40W/6 OHMS X 2

LEFT        RIGHT

 SPEAKER

 40W/6 OHMS X 2

LEFT        RIGHT

Fig. 1

Fig. 2

MENU

BAND

OK

A/B

DISP

Uninitialized 

State Detected

(Press OK)

MENU

BAND

OK

A/B

DISP

Regional Setup

 US and Canada

Western Europe

Australia

MENU

BAND

OK

A/B

DISP

Set TunerA Mode

 Standalone

 Source 1

 Source 2

Содержание NV-T2DAB

Страница 1: ...NV T2DAB Dual AM FM Tuner Installation Guide...

Страница 2: ......

Страница 3: ...closure that will impede the flow of cooling air 8 Do not install this product near any heat sources such as radiators heat registers stove or other apparatus including heat producing amplifiers that...

Страница 4: ...r s d eau comme par exemple baignoires viers piscine sous sol humides Etc 6 Utiliser exclusivement un chiffon sec pour nettoyer ce produit 7 Ne bloqu r aucune ouverture de ventilation Ne pas placer le...

Страница 5: ...ELECTRIC SERVICE ENTRANCE ANTENNA DISCHARGE UNIT NEC SECTION 810 20 GROUNDING CONDUCTORS GROUND CLAMPS POWER SERVICE GROUPING ELECTRODE SYSTEM NEC ART 250 PART H NEC NATIONAL ELECTRICAL CODE ANTENNA...

Страница 6: ...the Audio Outputs page 7 Setting the Audio Outputs for NuVoNet or Standalone use page 7 FM and DAB Antenna Installation page 8 Connecting for NuVoNet Use page 8 IR Control of the T2DAB page 8 RS232 Se...

Страница 7: ...SYSTEM NuVoNet IR INPUT L AUDIO R TUNER A L AUDIO R TUNER B R OUTPUT POWER OUTPUT POWER 20W 6OHM X2 20W 6OHM X2 SYS ON EXT MUTE L R L R L R VARIABLE OUTPUT FIXED OUTPUT SUM1 3033118 C US CONFORMS TO...

Страница 8: ...top selection Standalone will be highlighted This choice is used for any purpose that is not NuVoNet communication Using the down arrow on the far right of the front panel controls scroll to the desir...

Страница 9: ...indicated with up to five bars five being the best When listening to FM full stereo reception is indicated with an abbreviated ST 7 Menu This capacitive touch panel allows front access to the T2DAB s...

Страница 10: ...e NuVo audio systems or third party receivers and amplifiers 3 IR Input The T2DAB offers a single stereo mini 3 5mm connection for independent IR control of both tuners A and B 4 NuVoNet This single C...

Страница 11: ...ons step through the assigned presets The T2DAB is capable of 5 banks of 20 presets 6 Category Tune Category Tune is not implemented on this model 7 Pre This button is used to establish a preset bank...

Страница 12: ...put for the NuVo system and touching the OK button sets NuVoNet communication Once Output A is set the highlight will move to Output B For operation both outputs A and B must be set as Stand Alone or...

Страница 13: ...e is to take the IR output of your control device using a mono 3 5mm patch cable into the Direct IR input on the back panel of the T2DAB Tuners A and B feature discrete commands allowing both tuners t...

Страница 14: ...he DAB band is disabled for the tuner the DAB Channels menu will be greyed out The All Channels selection will display a list of the channels in the current service If a selection is a secondary chann...

Страница 15: ...h available To add a preset to favorites highlight and select an existing preset This will bring up a second menu with several choices Delete Preset which will erase the highlighted preset from the li...

Страница 16: ...al Setup The default regional tuning standard for FM defaults to Western Europe The other available choices are US and Canada Australia New Zealand and Custom Note that Custom is grayed out and can on...

Страница 17: ...SNR 31 dB Fig 16 Fig 17 Are You Sure No Yes Fig 18 Diagnostics Fig 16 Signal strength for AM FM and reception and the current firmware version number are provided in the Diagnostics menu Version This...

Страница 18: ...band This can also be done in the Bands menu selection If a band has been turned off see II T2DAB Front Panel Menu T2DAB Settings Enabled Bands pg 10 only the enabled bands will be present Tuning Mode...

Страница 19: ...ablished at the Tuner see Section I Setting the Audio Outputs for NuVoNet or Standalone use pg 7 Bands This displays the available broadcast bands for the selected tuner Presets Presets only appear if...

Страница 20: ...r down within the list of presets Move to Top and Move to Bottom places the highlighted preset in the number 1 position or to the last available position Seek Tune Selecting Seek Tune turns the freque...

Страница 21: ...ted version is downloaded to the Tuner the previous configuration will be overwritten To start a new configuration or open an existing configuration click on the Load Existing or Create New Configurat...

Страница 22: ...8 Fig 29 2 4 Auto On Fig 29 In the event of loss of power or if the Tuner is unplugged the tuners can be set with this check box to automatically turn on when power is returned Note that this feature...

Страница 23: ...is selected and a station name is typed into the Name field the Frequency dialer will become active As you scroll up and down the frequency list the highlighted Frequency column to the left will autom...

Страница 24: ...regions The Custom setting allows specific parameters to be set One determining factor for tuning is the Pre emphasis The two choices for this are 50 S microseconds and 75 S The custom setting also a...

Страница 25: ...USB to RS232 cable if your computer is not equipped with a serial port You can click on Help and then About to confirm communication between the computer and the Tuner The initial software screen wil...

Страница 26: ...load Fig 40 When the download is complete a final window will appear indicating that all information has downloaded successfully Actual download time will vary based on your computer s processing capa...

Страница 27: ...sted cETLus USA Safety Listing UL 60065 FCC CE Australia C Tick Canada Safety Listing CAN CSA C22 2 60065 03 ENERGY STAR Physical Specifications Unit Size Millimeters 44 H x 430 W x 250 D Unit Size In...

Страница 28: ...NuVo Technologies 3015 Kustom Dr Hebron KY 41048 USA www nuvotechnologies com Ph 859 817 7200 TNDAB 0839...

Отзывы: