2.6 Principle of Termination
Every device that is connected at the end of the communication data line must be
terminated by either the DIP switch setting or an appropriate device such as a
termination jumper to prevent potential control signal errors.
See Figure 7 for termination switch settings and Figure 8 for examples of devices
requiring termination. Note: Total length of the cable for communication should not
exceed 1.2Km or .74 mile.
SW2 1
2
3
4
Terminated ON
ON
X X
Not terminated
OFF
OFF
X
X
Pull Up/Down **
X
X
ON
ON
Normal **
X
X
OFF
OFF
Figure 7 - Setting Dome Camera Termination
** Unless communication error, put the position 3, 4 of the S1 in OFF state.
Position 3, 4 should be set as a pair. (Both 3, 4 to ON position or OFF position)