32
• VIEW ANGLE SETUP
VIEW ANGLE SETUP
PANNING RANGE
FLIP : AUTO
TILT ANGLE LIMIT : 00
SAVE AND EXIT(ESC TO CANCEL)
FLIP
OFF, AUTO
OFF:
The dome camera moves until 90
vertically.
AUTO:
When the camera reaches the floor directly above the moving object, it will stop.
At that time, release the
Joystick
instantly and pull it down again to run the auto-flip
function. When you use the panning range, it is recommended to use the flip mode to AUTO.
TILT ANGLE LIMIT
-10
~ 10
This option is designed to limit the view angle as there is some obstruction in zooming out on
specific areas of the tilt angle.
NOTE:
Focus issues may occur in certain conditions.
PANNING RANGE
When the dome camera is installed near a wall, panning range can be limited by user.
PANNING RANGE SETUP
(CTRL KEY)
RIGHT LIMIT : 000.0
LEFT LIMIT : 000.0
ENABLE : OFF
SWAP : OFF
AUTO PAN : ON
SAVE AND EXIT(ESC TO CANCEL)
1. Place the dome camera under 90 degree vertically.
2. Set “
RIGHT LIMIT
” by pushing the
Joystick
to the right.
3. Set “
LEFT LIMIT
” by pushing the
Joystick
to the left.
4. Set
“
ENABLE
” to ON to use.
To exchange the right and the left limit, set “
SWAP
” to ON.
To apply limits on the auto pan (endless panning), set “
AUTO PAN
” to ON.